Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Very good quality original datasheet!I like this amazing website!!!!!!
 ;
Excellent just what I needed to replace the electrolytic caps and make this old gem a beauty again. Was as scan of the original photocopied service manual.
 ;
It was helpful to get schematic with waveforms in important points and lot of service information. Manual is good quality, fast delivered. Of course it is hardcopy of paper one with all its disadvantages.
 ;
I want to give you a real heads-up for your desire to enable such people as I to acquire the information I need to maintain the older types of equipment such as this Akai HXA351W. You do a swell job with all the processes you have to perform so I can have a legible, thus usable
document which does not send me crazy trying to figure out the blurry text of a bad copy.
Very well done, Thomas.
 ;
This manual is very well presented and after printing out looks about as close to an original as I think you can get. The quality is second to none.
The content of the manual is comprehensive and I think it would be well suited to an audio repair professional which I'm not but I did find it very informative and helpful.
The cost of the manual is more than covered by the money I'll save when I change the keep memory battery now I have the relavant info.
Very pleased with my purchase and can recommend it wholeheartedly as I can other manuals I've downloaded from this site.
Regards
Limey Alex
(1) Monitor the waveform at the test point �TP-G�. (2) Click the [WMB] button and adjust to the specified level. (3) Check the voltage at the test points �TP-R� and �TP-B�. 2 (4) Click [Next] button. [Note] �G� and �B� levels also change when the [WMB] adjustment is performed. Recommendation value : E8 (min:E0 � max:F5) Input Signal : RGB flicker pattern (1) Select a red single color screen when adjusting R. Click the [WM6] button, and adjust the flicker level to minimum in both + and � directions, taking note of the data values. Then set data to the mid-point between the two previously noted values. (2) Adjust other colors to be the same, using [WM5] for green and [WM4] for blue. (3) Click the [Upside Down] button to change projection mode. (4) Adjust this mode in the same way. (5) Click [Next] buttons. Recommendation value : 40 � 50
3
(1) Monitor the waveform at test point �TP-R�. (2) Click the [W03] button and adjust to the specified level. 4 (3) Click [Next] button. [Note] A signal level rises when [�] is pushed. A signal level falls down when [+] is pushed.
(1) Monitor the waveform at test point �TP-G�. (2) Click the [W04] button and adjust to the specified level. 5 (3) Click [Next] button.
1-35
TLPB2 Service Manual Rev. 2.0
|
|
 |
> |
|