Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
THANK YOU FOR A GOOD TRANSACTION, NICE COPY, CLEAR
 ;
Very Good! All the diagram are easy to read, and its complete.
 ;
This was an excellent source of detailed assembly information on a device which is at least 12 years old. A very lucky find, coupled with great service.
 ;
Excellent Service Manual and best price on the Internet. This Service Manual covers everything you could ever need including full circuit schematics, component layout diagrams, stripdown procedure and full parts list/breakdown. I needed this to carry out a modification to one of these headunits and this manual covered everything I needed. Fast delivery, processed within a few hours.
 ;
Thought I would never find a copy of the Technics SX-EN2 Service Manual until I found Owner-Manuals.com. Price was very fair and I received the download promptly. While a photocopy, it is quite readable and includes all the pertinent information and diagrams. Thank you Owner-Manuals!
3) Observe the waveform on the spectrum analyzer and turn RV21 to adjust the modulation degree of a sub spectrum �A� in the figure 4 to be narrowest as shown below.
4) At this time, measure AC voltage of IC21 Pin 1 on the TX board with AC voltmeter and define the value as �V0� for the next adjustment. 5) Turn the RV21 again so that the AC voltage of IC21 Pin 1 becomes the same value as the two thirds of �V0�. (V1=V0 � 2/3) Adjustment Location: TX board (See page 6.) Adjustment and confirmation without a spectrum analyzer Please confirm the units by following procedure shown below. Here a series of procedure which can be performed without a spectrum analyzer is introduced. Deviation adjustment/confirmation 1) Input a 400 Hz 316 mV signal into the left channel of transmitter. 2) Measure the AC voltage at the Pin 1 of IC21 (MJM2100M) with AC voltmeter. Spec.: 100 ± 10 mVrms If not, turn RV21 for obtaining the value. Adjustment Location: TX board (See page 6.) Sub-carrier frequency and output level confirmation 1) No signal is input into transmitter. 2) Connect a oscilloscope and a frequency counter to the test point TP1. 3) Confirm the voltage is within the following spec. Spec.: 0.55 Vp-p
0.55 Vp-p
4) Confirm the frequency is within the following spec. fsub=42 ± 2 kHz
SCHEMATIC DIAGRAM
� Original Service Manual page 7. (Location C � E, 6 � 8) Connection point
PRINTED WIRING BOARD
� Original Service Manual page 5. (Location A � C, 4 � 6)
oscilloscope frequency counter IN
!:
[TX Board]
+ � OUT coaxial cable
^
[TX Board] � Conductor Side �
�5�
|
|
 |
> |
|