Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Very good quality scan of the document. I am very pleased with what I got.
 ;
PDF Contains
Technical Data, Mechanical data, Detailed Circuit diagram with components value, PCB layout. Actual PCBs Print. Component List, Spare parts code list and Input output detail. It cover LBB1211, LBB1212, LBB1213, LBB1216, LBB1217.
It is the actual Service Manual for SQ10
 ;
very good manual with clear electrical schemes. Very helpful to find wat was wrong inside my microwave.
 ;
Hi, thankyou for providing the Nordmende Globetrotter original manufacturer's repair manual. Quality is very good and sharp - the PDF file was comfortably small to download. The only question is: why did it take so long to become ready for download?? Many thanks anyway, I fixed the fault in the radio thanks to the circuit.
regards: Nick
 ;
This was super service.Ordered this manual and was reading the download an hour later
GX20
Hands free kit (Headset) When replacing the hands free kit, output avilable?
NO
CONFIDENTIAL
YES
Hands free kit defective.
Voltage of 1 to 1.9 V applied to JK301 3 pin?
NO
YES
E
Voltage of 1 to 1.9 V applied to TP106?
NO
YES
Parts of L105 to JK301 3 pin defective.
Voltage of more than 2.4 V applied to Q101 3 pin?
NO
YES
Parts of Q101 3 pin to L105 defective.
YES
Q101 defective.
Voltage of 3 V applied to Q101 2 pin?
NO
IC104 defective.
G E
Voltage of approx. 1 V applied to IC102 44 pin?
NO
YES
F
Voltage of approx. 1 V applied to IC102 40 pin?
NO
YES
IC102 defective.
Voltage of more than 2.4 V applied to Q101 3 pin?
YES
NO
G
Parts of R107, R108, C113 and L106 defective or soldering defective.
F
Voltage of 0 V applied to C186 (IC102 6 pin side)?
NO
YES
IC102 defective or soldering around C186 and R184 defective.
JK301 defective or R184 defective.
2 � 48
|
|
 |
> |
|