Excellent Service Manual and best price on the Internet. This Service Manual covers everything you could ever need including full circuit schematics, component layout diagrams, stripdown procedure and full parts list/breakdown. I needed this to carry out a modification to one of these headunits and this manual covered everything I needed. Fast delivery, processed within a few hours.
;
Thought I would never find a copy of the Technics SX-EN2 Service Manual until I found Owner-Manuals.com. Price was very fair and I received the download promptly. While a photocopy, it is quite readable and includes all the pertinent information and diagrams. Thank you Owner-Manuals!
As there is occurrence of convergence distortion after completing the landing adjustments, be sure to carry out convergence adjustments. If the color irregularities in the screen�s corner section are not improved, correct them with the landing magnet. After using the landing magnet, be sure to demagnetize the CRT with degausser and verify that there is no occurrence of color irregularity. (refer to Fig. 1-6) Landing magnet: 81-JTI-710-010 (two-sided adhesive tape) : 80-XVI-218-010 Cushion
In Fig. 1-7, two 4-pole magnets are stacked together so as to be of the same polarity. Move the B and R beams to their respective direction, by rotating the two 4-pole magnets together. By adjusting the opening of the two magnets, it is possible to adjust the amount of the beam�s movement.
N S
B G R
S S N N
B G
N
R
S
N S
S
N
Fig 1-8 In Fig. 1-8, the two 6-pole magnets are stacked together so as to be of the same polarity. Move the B and R beams to their respective direction, by rotating the two 6-pole magnets together. By adjusting the opening of the two magnets, it is possible to adjust the amount of the beam�s movement. (1) Receive the dot pattern signal from the pattern generator. (2) Pay attention to the center of the screen, and perform adjustments with two 4-pole magnets so that the R beam and B beam are perfectly aligned and become a magenta color. (Refer to Fig. 1-2) (3) In the same way, pay attention to the screen, and perform adjustments with a 6-pole magnet so that the magenta beam and G beam are aligned and become a white dot. (Refer to Fig. 1-3) (4) After adjustments are completed, secure all magnets with the lock link. (Refer to Fig. 1-4) Since the landing magnet is polarized, check the screen�s improvement through rotation, not only by position.
Landing magnet Cushion
1-5.The Surrounding Convergence Adjustment
Perform this adjustment after completion of adjustment 1-4. (1) Shake the deflecting yoke up, down to the right and left, and adjust any discrepancies in the screen�s surroundings. (2) Insert wedges in three locations in the gap between the deflecting yoke and the surface of the CRT funnel in order to secure the deflecting yoke. (Refer to Fig. 1-9)
Fig 1-6
1-4. Beam Center Convergence Adjustment
Make adjustments on the convergence with 4-pole and 6-pole magnets. Operate each magnet in relation to the electron beam as shown in Figs. 1-7 and 1-8. When performing this adjustment, verify whether there is distortion in the focus adjustment. If necessary, carry out adjustments again.
S S B N G N R S S N B G R N
Wedge
Wedge
Wedge Position of wedge
Fig 1-7
Fig. 1-9
30
|
|
|
> |
|