Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I was having a hard time finding the problem with this Mackie 1604 unit. I didn't have a schematic. Went looking on the web and found your site and the price was more then reasonable. Ordered it and within the hour had the manual and within 15 minutes had the unit fixed. Best $4.99 I ever spent. Thank you.
Doug
 ;
This is a service manual in every sense of the word ( French and German versions of the text are included, as well as English..)
There are explanations of the mechanical and electrical functions, plenty of mechanical drawings, and the needed schematics. The quality of the scanning is excellent - all the component values are clearly legible - and very usefully there are pcb component layouts, so you can find a component on the schematic, and then very quicky pinpoint its physical location on the relevant pcb.
I cannot see how I can give this manual any less than the maximum 5 stars! Great value for money, which will pay for itself immediately. Excellent all round!
 ;
the manual is great and especially hard to find... thanks for the great service and having a hard to find manuel_
 ;
Please tell us what you think and share your opinions with others. Be sure to focus your comments on the product. You will receive $2.50 of store credit for Your review.
 ;
hat alles sehr gut geklappt. Das Servicemaual ist gut zu verwenden. Die Pläne und Schrift
ist klar und leserlich. Außerdem preiswert. Grüße an alle Hifi-Bastler
NOTICES BEFORE REPAIRING
To make the best use of this equipment, make sure to obey the following items when repairing (or mending).
1. Do not damage or melt the tunicate of the leading wire on the AC1 side, including the power supply cord. 2. Do not soil or stain the letters on the spec. inscription plates, notice labels, fuse labels, etc. 3. When repairing the part extracted from the conducted side of the board pattern, fix it firmly with applying bond to the pattern and the part. 4. Restore the following items after repairing. 1) Conditions of soldering of the wires (especially, the distance on the AC1 side). 2) Conditions of wiring, bundling of wires, etc. 3) Types of the wries. 4) Attachment conditions of all types of the insulation. 5. After repairing, always measure the insulation resistance and perform the voltage-withstand test (See Fig-1). 1) The insulation resistance must be 7.0 ~ 9.5 M� when applying 500V per second. 2) In the voltage withstand test, apply 3 kV for 1 min and check that the GO lamp lights. * * * * Breaking current set to 6 mA. Connect the safety checker as shown in Fig-1, then measure the resistance and perform the test. Do not touch the equipment during testing. For details of the safety checker, refer to the supplied Operation manual. Insulation resistance: 7.0 ~ 9.5 M� (500 V/s) Voltage-withstand: 3 kV for 1 min
Safety checker (Model 7110, etc.)
Earth cable
AC cable
Connect the earth cable to the outside metal part terminal.
Fig-1
When servicing and checking on the TV, note the followings.
1. Keep the notices. As for the places which need special attentions, they are indicated with labels or seals on the cabinet, chassis and parts. Make sure to keep the indications and notices in the operation manual. 2. Avoid an electric shock. There is a high voltage part inside. Avoid an electric shock while the electric current is flowing. 3. Use the designated parts. The parts in this equipment have the specific characteristics of incombustibility and withstand voltage for safety. Therefore, use a part which has the same character as the replaced part. Especially as to the important parts for safety which is indicated in the circuit diagram or the table of parts with a ! mark, the designated parts must be used. 4. Put parts and wires in the original position after assembling or wiring. There are parts which use the insulation material such as a tube or tape for safety, or which are assembled so that these parts do not make contact with the printed board. The inside wiring is designed not to get close to the pyrogenic parts and high voltage parts. Therefore, put these parts in the original positions. 5. Take care of the cathode-ray tube. By setting an explosion-proof cathode-ray tube in this equipment, safety is secured against implosion. However, when removing it or servicing from the back, it gives out shock that is dangerous. Take enough care to deal with it. 6. Avoid an X-ray. Safety is secured against an X-ray by giving considerations to the cathode-ray tube and the high voltage peripheral circuit, etc. Therefore, when repairing the high voltage peripheral circuit, use the designated parts and do not change the circuit. Repairing, except indicates, causes rising of high voltage, and the cathode-ray tube emits an X-ray. 7. Perform a safety check after servicing. Confirm that the screws, parts and wiring which were removed in order to service are put in the original positions, or whether there are deteriorated portions around the places serviced.
�3�
|
|
 |
> |
|