Who's Online
There currently are 5928 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Excellent manual, detailed, very useful! Exactly what I needed, I'd recommend it to all who need it. Although images are scanned easily readable and explicit. A valuable tool product at a price more than modest, take it with confidence and you will not regret it!
;
Clear and complete service manual. Easy now to restore my old Kenwood KD-1500.
Thanks a lot.
;
Thanks for this "hard to find" service manual. This Sony PS212A is a very good turntable that needed to be restored !
;
Excellent quality on these manuals. Same as having the original printed manual and incredibly useful when doing a custom install like me. Keep it up on the good work.
;
This is an excellent information source. Great quality and tons of info regarding technical service for the Technics SH8065.
(5)
Push the anode cap with your thumb in the direction of arrow 1 as shown in the figure, then lift the cap in the direction of arrow 2 to release the hook on one side. (See Figure 2-3)
Anode cap
CRT
Hook
CRT Hook
Figure 2-3
(6)
Turn over the anode cap on the side where the hook was released and pull out the cap in the direction opposite to that on which the cap was pushed. (See Figure 2-4) Caution : Do not pull out the anode cap straight up. : Do not pull the cap forcibly. After removing the cap, check that the hook is not deformed.
Anode cap
CRT Anode button Hook
Figure 2-4
3. ANODE CAP REINSTALLTION
Observe the cautions carefully so that no accident occurs due to a defect in installing the anode cap and so it does not come off.
Left
Anode cap
Right
3-1. Caution before Reinstalling
Never turn the anode cap after installing it Never re-use the hook when it has been deformed (1) If the anode cap is turned after it is installed, it may come off. Therefore, arrange the high-voltage cable before attaching the anode cap. (See Figure 3-1) If you have attached the anode cap before arranging the high-voltage cable, arrange the cable carefully so the cap does not turn. Figure 3-1
(2)
3-2. Anode cap reinstallation
(1) Use a clean cloth moistened slightly with alcohol to clean the installation section. (See Figure 3-2) Caution : Check that the installation section is free from dust, foreign matter, etc. Coat the anode cap installation circumference with an appropriate amount of the specified silicone grease (KS650N). Caution : Be careful that silicone grease does not enter the anode button.
Anode button
(2)
Installation section
Figure 3-2