I was very skeptical of this website, I have never downloaded manuals before. I put it on the AMEX and payed through Paypal to ensure protection. I got the manual exactly as described and now I can replace the filter capacitor for this amp. Great Price, others selling for 12.99 or more and this is the same manual. I will search out this website for other manuals. Thank you
(5)
Push the anode cap with your thumb in the direction of arrow 1 as shown in the figure, then lift the cap in the direction of arrow 2 to release the hook on one side. (See Figure 2-3)
Anode cap
CRT
Hook
CRT Hook
Figure 2-3
(6)
Turn over the anode cap on the side where the hook was released and pull out the cap in the direction opposite to that on which the cap was pushed. (See Figure 2-4) Caution : Do not pull out the anode cap straight up. : Do not pull the cap forcibly. After removing the cap, check that the hook is not deformed.
Anode cap
CRT Anode button Hook
Figure 2-4
3. ANODE CAP REINSTALLTION
Observe the cautions carefully so that no accident occurs due to a defect in installing the anode cap and so it does not come off.
Left
Anode cap
Right
3-1. Caution before Reinstalling
Never turn the anode cap after installing it Never re-use the hook when it has been deformed (1) If the anode cap is turned after it is installed, it may come off. Therefore, arrange the high-voltage cable before attaching the anode cap. (See Figure 3-1) If you have attached the anode cap before arranging the high-voltage cable, arrange the cable carefully so the cap does not turn. Figure 3-1
(2)
3-2. Anode cap reinstallation
(1) Use a clean cloth moistened slightly with alcohol to clean the installation section. (See Figure 3-2) Caution : Check that the installation section is free from dust, foreign matter, etc. Coat the anode cap installation circumference with an appropriate amount of the specified silicone grease (KS650N). Caution : Be careful that silicone grease does not enter the anode button.
Anode button
(2)
Installation section
Figure 3-2