thank u so much for this manual that was so cheap that i thought it was a scam but i gambled anyway because it was too good of a deal to pass up and behold,the manual has everything and details of everything even the screws and im still amazed and very happy with my manual .so take my word and jump on it before they realize how cheap they selling thier manuals..thank you so much for taking time to read my thoughts
9. Vertical Center Input signal: Crosshatch Measuring instrument: Pattern generator/PAL 9-1. Set the TV to the "Normal I" mode. 9-2. Choose V. Shift from the menu screen. 9-3. Adjust the "Vol +/-" buttons on the remote control so that the dot mark at the center of crosshatch is positioned at the vertical center of screen.
10-2. S-Correction 1) Choose V. S Cor from the menu screen. 2) Perform adjustment in the same way as with 6-1 Slope. * Repeat adjustments 10-1 and 10-2 so that A=B=C is available. 10-3. Amp 1) Choose V. Amp from the menu screen. 2) Adjust the "Vol +/-" buttons on the remote control so that the dot mark at the center of crosshatch is positioned at the vertical center of screen, the circle is a perfect circle, and each crosshatch is square. * If vertical center is not correct, perform adjustment in 5. Vertical Center again.
CRT center mark
Fig.9-1
A
10. Vertical Size Input signal: Crosshatch (with circle) Measuring instrument: Pattern generator/PAL Set the TV to the "Normal I" mode for adjustment items 10-1 _ 10-3. 10-1. Slope 1) Choose V. Slope from the menu screen. 2) Adjust the "Vol +/-" buttons on the remote control so that the vertical length of each square is equal (A=B=C).
A
Fig.10-2
B
11. AGC Input signal: Color bar (ANT RF=Input) Measuring instrument: Pattern generator/PAL Test point: 1501 6 pin RF AGC 11-1. Receive the pattern generator frequency at Pr91. 11-2. Connect an oscilloscope to the test point. 11-3. Choose AGC from the menu screen. 11-4. Use the "P " button on the remote control so that the voltage at the test point is 2.5 VDC.
C Fig.10-2