Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is a great site. I placed my order and by the next am it was available for download. Had some problems with some missing copy on some pages. Once I brought the error to the OMC's attention, the issue was resolved. I'll come back again.
 ;
Mi spiace per non poter scrivere in inglese... ma sono veramente soddisfatto del servizio offerto. Grazie..!!
 ;
The quality of this manual is good. It has all schematics and setup information for both the MDS-B3 and the MDS-B4. The scan quality is quite good, all pages are readable, This service manual also contains scans of the operating instructions from the User manual.
 ;
Quick site processing. A complete and very useful manual with all details. Thank you!
 ;
Das Service Manual war von der ersten bis zur letzten Seite sehr informativ und hilfreich. Die Darstellung aller Teile war klar und der Text gut lesbar.
Vielen Dank, das war nicht der letzte Download bei ownner-manuals.com.
TX-SR304/304E OPERATION CHECK-2
SPEAKER PROTECT-2 (CURRENT DETECTION)
[When] 1. Exchange power IC (Q6001, Q6002). 2. Exchange amplifier PC board ass'y (NAAF-8745). [Procedure] <Note> No input. Do not check two or more channels at the same time. Do not connect a dummy load to speaker terminal longer than 2 seconds. 1. Press and hold down CD button, then press STANDBY/ON button while the unit is powered on. " Test - _ " is displayed only for 5 seconds.
Test - _
Blinks
2. Press VIDEO 3 button, while " Test - _ " is displayed. The unit will be in the state of " Test-4-00 ".
Test - 4- 00
3. Repeatedly press TONE+button until " Test-4-29 " is displayed.
Test - 4- 29
4. Connect the dummy load of 3 ohms to the Front L ch speaker terminals. At this time, confirm that the speaker relay is not turned off.
Test - 4- 29
5. Connect the dummy load of 1 ohm to the Front L ch speaker terminals. At this time, confirm that the speaker relay is turned off and " Protect " is displayed.
P rotect
Disconnect the dummy load immediately after checking the display of " Protect ".
Test - 4- 29
6. Check other channels according to the same procedure as 4 and 5. FL FR C SL SR SW Turn off
7. Press the STANDBY/ON button.
Cl ear
|
|
 |
> |
|