Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
The service manual is as described and received the link to the download sooner than expected. Great service, quality product. This site is a big help in the electronics repair business.
 ;
Il service manual molto accurato. Rapidi nella risposta
 ;
Quick site processing. A complete and very useful manual with all details. Thank you!
 ;
Quick service response. A useful and very rare service manual with all details. I recomend this service.
 ;
I ordered this manual sometime in the afternoon and I received it on my e-mail the same evening.
This is a fantastically good and properly scanned copy of the original manual. All pages are of the same scale and they overlap each other. It means that you can print the manual and easily make it as a convenient paper manual.
The content of the manual is fantastic. Alignment descriptions, PCB layouts and elementary diagrams are explicit and precise. I immediately found what I was looking for. Thanks to this manual and Owner-Manuals.com my amplifier is alive again. Many thanx indded!
TX-SR402/8240/HT-R420 OPERATION CHECK-1
DC VOLTAGE DETECTION PROTECTORS
[NOTE1] Limit time to apply voltage is 0.5 - 1.0 seconds each channel. When protection operation does not occur at once, try several times. [NOTE2] Don't connect speakers or any load. Don't short speaker terminals. 1. Set the unit to test mode " Test-1-00 " . 1-1. Press and the hold down the CD button , then press the STANDBY/ON button when the unit is Power ON.
Te st - _
1-2. Press the DVD button, while the display of "Test - _" has come out. Unit will be in the state of " Test-1-00 ".
Te st - 1-00
2. Apply DC voltage (+1.5 to +3V) to MULTI CHANNEL (FL, FR, SL, SR, C, SW) terminal, each channel. 3. Check that "protect" is display come out. 4. Apply DC voltage (-1.5 to -3V) to MULTI CHANNEL (FL, FR, SL, SR, C, SW) terminal, each channel. 5. Check that "protect" is display come out. 6. Press the STANDBY/ON button.
Disappears
Clear
CURRENT DETECTION PROTECTORS
[NOTE] In the state of testmode"Test-4-29", the pulse waveform for checking from speaker terminal outputs automatically. Therefore, oscllator is unnecessary. 1. Set the unit to test mode "Test-4-29" 1-1. Press and the hold down the CD button , then press the STANDBY/ON button when the unit is Power ON.
Te st - _
1-2. Press the VIDEO3 button, while the display of "Test - _" has come out. Unit will be in the state of "Test-4-00".
Te st - 4- 00
1-3. Repeat and press SPEAKERS B until the display of "Test-4-29" comes out.
Te st - 4-29
2. Connect the lord resister (3ohms) to the speaker terminals. 3. Check the not displayed "PROTECT" and speaker relays not turn OFF. 4. Check the each speaker terminals. 5. Connect the lord resister (1.5ohms) to the speaker terminals. 6. Check the displayed "PROTECT" and speaker relays turn OFF immediately. 7. Check the each speaker terminals. 6. Press the STANDBY/ON button. Disappears
C lear
|
|
 |
> |
|