This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
TX-SR603X/603E/8360 OPERATION CHECK-3
CONTROL OF POWER SUPPLY (OUTPUT SENSOR AND THERMAL SENSOR)
[When] 1. Exchange power transistors (Q6050 - Q6066). 2. Exchange power amplifier PC board ass'y (NAAF-8523). 3. Exchange thermal sensor PC board ass'y (NAETC-8526). [Procedure] <Note> No output. No input. Output sensor 1. Press and the hold down the CD button , then press the STANDBY/ON button when the unit is Power ON. " Test - _ " is displays it only for 5 seconds.
Test - _
Blinks
2. Press the VIDEO 3 button, while the character of " Test - _ " is displayed. Unit will be in the state of " Test-4-00 ".
Test - 4-00
3. Repeatedly press TONE+ button until the character of " Test-4-37 " is displayed.
Test - 4-37
4. Adjusts MASTER VOLUME to Max. position. At this time, check the character of " FM STEREO " displayed. And, check relay RL6901 and RL6902 are turned off in 2 - 3 seconds.
Test - 4-37
5. Press the STANDBY/ON button.
FM STEREO
Turn off
Clear
Thermal sensor
1. Press and hold down the DISPLAY button, then press the STANDBY button when the unit is power ON. " V e r . 0 . 5 0 / 0 5 1 3 1 a " is displays it only for 2 seconds. <Ex.>
Ver. 0.50/05131a
2. Press the TONE button, while the character of " Ver.0.50/05131a " is displayed. <Ex.>
T: 25 C/ 77 F
3. Check the displayed temperature is +/-20 C of the ambient temperatures. 4. Press STANDBY/ON button.
Turn off
Clear
|
|
|
> |
|