|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This manual was exactly what i needed and could not find elsewhere. Price is not too high. Great !
 ;
ecelent I was reciver the service manual soon I fell so happy very complete 100% positive all by this store tanks atte Luis salazar
 ;
A great copy of the manual, and the only one I could find anywhere on the net! The circuit diagrams are easily readable, all component values marked and easy to see. A highly appreciated download!
 ;
Great Manual. This manual is available no where else. It was exactly what I was looking for.
 ;
The TEAC A-1500's Service Manual was instrumental in reviving this classic reel-to-reel. Not only does it have the schematics, exploded parts diagram and parts list, it also provided mechanical adjustment information that approximate factory default settings.
ITEM Program Menu
y Test Meter c Test Point P Pattern
JOB
CODE
Input Signal
Operation
Adjusting Value
STANDARD SETTING
D11 3) Adjust VSR setting H-DUTY P Crosshatch y Osc scope c TP2 ~ GND D12 D13 D14 ModeHIGH H. DRIVE +B y Digital Voltmeter c TP1 ~ GND VSR SETTING P Crosshatch D16 D15 Check that the input signal to the monitor is [fH 71.0kHz] and [fV 184.0Hz]. Set the cell to 2) Adjust VSR setting , and press [ ]. Set the cell to INTP [ 1 ] and press [ ]. Set the cell to H-Duty and press [ ] Make the adjustment to the value shown at right by using [ ] and [ ]. Set the cell to H. DRIVE +B and press [ ]. Make the adjustment to the value shown at right by using [ ] and [ ]. Change to the pattern at left. Set the cell to following items, and make the adjustment to the value shown at right by using [ ] and [ ]. q H. SIZE w H. POSITION e V. SIZE r V. PCC GAIN t V. PCC. CORNER y V. PCC BALANCE q : 310mm ± 5 e : 232mm ± 5 w : Center rty:
t T
Duty = t = 48% T ±2% 12.0V ± 0.2V
D
H-DAF Balance
P Full dots y OSC SCOPE c TP6 ~ GND
D17
Set the SCOPE to 5 us/DIV. Set the cell to H-DAF balance. Make the adjustment to the bast point at right by using [ ] and [ ].
TP6 Video input Best point H-DAF Balance = Best point
H-DAF Gain
P Full dots y OSC SCOPE c TP6 ~ GND
D18
Set the SCOPE to ? ms/DIV. Set the cell to H-DAF Gain. Make the adjustment to the value shown at right by using [ ] and [ ].
H-DAF Gain
D19 D20
To register by press [ ]. Store factory preset data. OK (y/n) Then press [Y] and [ ].
H-DAF Gain = 690V ± 40Vp-p
� 24 �
|
|
 |
> |
|