Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
complete part-lists and pcb layout, schematic diagram is good enlargable,
 ;
Excellent, fast delivery, excellent product. Good luck!
 ;
This manual is for the usa model only. But it is clear
, accurate and comprehensive, including board layouts and schematics.
I found it extremely useful for my mitsubishi dp-86da, but the same diagram would also work for the realistic lab5000 and hi fi 80. Thanks.
 ;
Great to have extra resources for Service Manuals, Now days you can really not trouble shoot efficiently without one , Wayne at IRIONS TV & ELECTRONICS REPAIR Clearwater , Fl. 33755 727-446-7955
 ;
For five bucks you can barely buy a hamburger. Or for the same five bucks you can buy a service manual. Much more useful. (and better for your health, depending on where you buy your hamburgers).
Yes, there are free manual sites out there, but if they don't have what you want, you have to pay.
And five bucks isn't much. Not for full specs, schematics and adjustment and parts replacement procedures.
My only criticism is that grayscale illustrations aren't well rendered, but I've seen worse.
Schematics and text are clear.
I'll be happy to purchase from here again.
Mike
[email protected]
Final check after repair
3.7
Final check after repair
Final check after repair The �nal check after repair, describes the activities that are needed to ensure the product will be returned in perfect condition to the customer. The contents is: AC leakage test. Check product information. Restore the setup and check connections, picture and sound. Final cleaning of the product. PIN-code setting.
AC leakage test
The scope of the test is, to check the antenna terminals and other exposed metal parts for AC leakage. 1. 2. 3. 4. Remove the line cable from the AC source (the wall outlet). Place a jumper across the two AC plugs prongs. Use a multi-meter, set for measurements in the ohm-area. Place one lead from the multi-meter on the AC plug and place the other lead on each of the exposed metal parts, that is antenna connections and other exposed metal parts on the rear panel of the product. The resistance during these measurements must be of 1 Mega Ohm or more. If resistance is below 1 Mega Ohm, this indicates an abnormal situation and corrective actions must be taken.
5.
Insulation test Each set must be insulation tested after having been dismantled. Make the test when the set has been reassembled and is ready to be returned to the customer. Flashovers must not occur during the testing procedure! Make the insulation test as follows: Short-circuit the two pins of the mains plug and connect them to one of the terminals of the insulation tester. Connect the other terminal to ground on the aerial socket. NOTE! To avoid damaging the set it is essential that both terminals of the insulation tester have good contact. Slowly turn the voltage control of the insulation tester until a voltage of 1.5 kV and max. 10mA is obtained. Maintain that voltage for one second, then slowly turn it down again. Insulation test at the customer Remove the mains cable from the wall outlet. Place a jumper across the two AC plug prongs. Use a multi-meter, set for measurements in the Ohm-area. Place one lead from the multi-meter on the AC plug and place the other lead on ground at the Power Link plug. The resistance during this measurement must be of 1 Mega Ohm or more. Resistance measured below 1 Mega Ohm indicates an abnormal situation and corrective action must be taken.
|
|
 |
> |
|