Abgleichvorschriften / Adjustment Procedures
UMS 100
CD
Messgeräte: Oszilloskop, Digital-Voltmeter, Test-CD Abgleich 1. HF-Verstärker Vorbereitung Oszilloskop an Messpunkte H und I (GND). CD einlegen und Wiedergabe starten. Abgleichvorgang Mit VR1 i auf maximale Amplitude abgleichen.
2. EF-Balance
Oszilloskop an Messpunkte J und I (GND). CD einlegen und Wiedergabe starten. Taste T drücken und gedrückt halten.
Mit VR2 j auf symmetrische Kurvenform abgleichen.
A A=B B
3. Tracking Offset
Digital-Voltmeter an Messpunkte J und I (GND). CD STOP. VR4 r auf Mittelstellung.
Mit VR3 u auf 0V ± 100mV abgleichen. Mit VR4 r auf 0V ± 5mV abgleichen.
j J H i ur I
2-3
GRUNDIG Service
|
|
 |
> |
|