Who's Online
There currently are 6035 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
I'm very happy that you all are performing an incredible good job. Furthermore what you did is very useful for all people as me that have electronics as an hobby.Thank you!!!!!
;
Manual found fast and good quality, very helpfull service
;
8-17-12 Been using the sight for about 6 months. Fast Downloads and top quality
Manuels !
;
Everything was great, the manual, the response time, the simplicity of the order, and the
Price. The only thing that I could possible say on a negative note would be that the manual I ordered was more for a service tech. There were a lot of schematic diagrams that didn't help me solve the problem. However I would order again and recommend the web sight to others.
;
I'd been looking for this manual for awhile. Exactly what I needed - and at an excellant price. Thanks!
CHAPTER 5. MASTER RESET (ALL MEMORY CLEAR)
There are three possible methods to perform a master reset. 8) MASTER RESET-1 is executed. DISPLAY:
1. MRS-1 (Master Reset-1): Clear the entire memory and resume initial values.
PROCEDURE
1) Turn off the AC power switch. 2) Set the reset switch to the "ON" position. 3) Turn on the AC power switch. 4) Set the reset switch to the "OFF" position. 5) The reset menu window is displayed as shown below. DISPLAY:
MASTER RESET
9) After completion of the master reset, the buzzer sounds three times and the following SRV mode display is shown. DISPLAY: [SRV mode screen]
Please select
PROGRAM RESET
MASTER RESET
Touch the [MASTER RESET] key. 6) The master reset menu window is displayed as shown below. DISPLAY:
Please select MASTER RESET MASTER RESET 2 MASTER RESET 3
2. MRS-2 (Master Reset-2): Clear the entire memory and resumes initial values.
The keyboard must be entered by hand. This reset is used if an application needs different keyboard layout other than that supplied by a nor-
Touch the [MASTER RESET] key. 7) The secret number entry window is displayed as shown below. DISPLAY:
mal MRS-1.
PROCEDURE
1) Turn off the AC power switch. 2) Set the reset switch to "ON" position.
ENTER PASSWORD
3) Turn on the AC power switch.
ENTER
CLEAR
4) Set the reset switch to the "OFF" position. 5) The reset menu window is displayed as shown below.
7 4 1 0
8 5 2 00
9
DISPLAY:
6 3
CANCEL
Please select
PROGRAM RESET
MASTER RESET
Enter the secret number for the MASTER RESET-1 and touch the [ENTER] key. The secret number for MRS-1: 11111111
UP-3301VS
Touch the [MASTER RESET] key.
MASTER RESET (ALL MEMORY CLEAR)