Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
- Very good scan quality, PERFECT!
- Sehr gute scan Qualitaet, empfehlenswert!
Wolfgang Sundhaus
 ;
Good site, works ok and you get what you order, no problems experienced, got my manual within a day. A++++
 ;
Original well scanned manual. Got the job done. Microwave problem found & corrected. For $5 and a new magnitron from ebay, it was a cheap and good the first shot fix. Electrical schematics allowed me to mage sure every thing else was ok before cutting and order for parts. Hard to live without.
 ;
I was very skeptical of this website, I have never downloaded manuals before. I put it on the AMEX and payed through Paypal to ensure protection. I got the manual exactly as described and now I can replace the filter capacitor for this amp. Great Price, others selling for 12.99 or more and this is the same manual. I will search out this website for other manuals. Thank you
 ;
Manual was reasonably easy to follow. I am not an engineer or know much about electronics but with the manuals help I was able to figure out the problem, identify the part required for the repair. Replacement part cost around $30. Whilst replacing the part I was telling myself, "this aint gonna work cos it seems far too easy". Took about 15 minutes to do and my plasma TV works a treat. Would never have been able to do this without the service manual.
CHAPTER 5. MASTER RESET (ALL MEMORY CLEAR)
There are three possible methods to perform a master reset. 8) MASTER RESET-1 is executed. DISPLAY:
1. MRS-1 (Master Reset-1): Clear the entire memory and resume initial values.
PROCEDURE
1) Turn off the AC power switch. 2) Set the reset switch to the "ON" position. 3) Turn on the AC power switch. 4) Set the reset switch to the "OFF" position. 5) The reset menu window is displayed as shown below. DISPLAY:
MASTER RESET
9) After completion of the master reset, the buzzer sounds three times and the following SRV mode display is shown. DISPLAY: [SRV mode screen]
Please select
PROGRAM RESET
MASTER RESET
Touch the [MASTER RESET] key. 6) The master reset menu window is displayed as shown below. DISPLAY:
Please select MASTER RESET MASTER RESET 2 MASTER RESET 3
2. MRS-2 (Master Reset-2): Clear the entire memory and resumes initial values.
The keyboard must be entered by hand. This reset is used if an application needs different keyboard layout other than that supplied by a nor-
Touch the [MASTER RESET] key. 7) The secret number entry window is displayed as shown below. DISPLAY:
mal MRS-1.
PROCEDURE
1) Turn off the AC power switch. 2) Set the reset switch to "ON" position.
ENTER PASSWORD
3) Turn on the AC power switch.
ENTER
CLEAR
4) Set the reset switch to the "OFF" position. 5) The reset menu window is displayed as shown below.
7 4 1 0
8 5 2 00
9
DISPLAY:
6 3
CANCEL
Please select
PROGRAM RESET
MASTER RESET
Enter the secret number for the MASTER RESET-1 and touch the [ENTER] key. The secret number for MRS-1: 11111111
UP-3301VS
Touch the [MASTER RESET] key.
MASTER RESET (ALL MEMORY CLEAR)
� 20 �
|
|
 |
> |
|