El producto satisface las necesidades del servicio t
;
This is a good quality scan of the Operation & Maintenance (Service) Manual for the PAL version of this high-band broadcast umatic, BVU-800P
All schematics and lineup procedures appear to be included in this one manual AFAICT.
The file size is just over 113 MB which gives an idea of the quality and number of pages.
All of the schematics, which contain some fairly small print, are easily readable when you zoom into the page.
John Thompson, Newcastle Upon Tyne, England.
;
Good quality, all schematics of few of models. There is also short form of user manual and regulation manual.
;
Perfect copy of the service manual. you can enlarge every page, and it comes up
with all details.
;
It´s very very nice manual with all, what i need. Original in good quality. Very fast business. Very much thanks...
Symbol/PartsCod) -------------------------------------------------------
MRS-3 (Master resetting 3)
Master resetting 3 requires the entry of Serial No. data in addition to Master resetting 2. After completion of the MRS-3, the following operations and programming will be inhibited. 1. GT programming. 2. All memory download via RS-232. 3. GT resets with Z report. (Z report can be made, but the GT will not be reset.)
Procedure
1) Turn off the AC switch. 2) Set the reset switch to the "SRV" position. 3) Turn on the AC switch. 4) While holding down the JOURNAL FEED key and MRS-3 key, turn to the (SRV) position from the (SRV�) position. MRS-3 key : UP-600=[CANCEL] key UP-700=[PLU72] key 5) The product serial No. input window is displayed as shown below. DISPLAY:
SERIAL No. 00000000
Enter the product serial No. of this POS and enter the [CA/AT] key. 6) Key position assignment: After the execution of MRS-3, only the RECEIPT FEED and JOURNAL FEED keys can remain effective on key assignment. Any key can be assigned on any key position on the main keyboard. [key setup procedure]
MRS-2 executed
0
Key position set
*2 Free key
0
*1
Free key setup complete.
Disable
MASTER RESET
NOTES: *1: When the 0 key is pressed, the key of the key number on the display is disabled. *2: Push the key on the position to be assigned. With this, the key of the key number on the display is assigned to that key position. *3: When relocating the keyboard, the PGM 1/2 modes the use standard key layout. Key No. 001 002 003 004 005 006 007 008 009 010 Key name Key No. 011 012 013 014 015 016 017 018 019 020 Key name Key No. 021 022 023 Key name
|
|
|
> |
|