Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
The item received was as described, as expected. I was pleased with the order. Thank you.
 ;
Superb rendition. Drawings (schematics) complete and unabridged. I do a great deal of vintage audio restoration. Documentation is essential for successful repairs. I have found sources over the years that offer good documentation, but rarely all that is necessary. Owner's Manuals has filled that void with complete and legible documentation. They have narrowed my "favorites" to a more manageable collection. This Denon manual in particular contained the latest revisions level, and offered alterations favorable to updating the item. The Illustrated Parts Breakdown (IPB) was well enough detailed to simplify part symbols and physical locations. You will not be disappointed!
 ;
Clear and concise. Saved me a lot of time and money.
 ;
Superb manual. Exactly what I ordered and made available in a very timely manner.
 ;
very fast detailed and accurate hope to do business again
s) Ribbon code sensor/luminance quantity adjustment (CN5-3, 19) Function : This is a transmission type sensor that reads ribbon code and starting mark on the ink ribbon. Pair LED luminance is set to obtain the most suitable luminance quantity. When reading ribbon code every time, the threshold level value for judging L or H is changed to the most suitable value. Level : Ribbon code portion is H, others are L Check method : Make sure the threshold level, ribbon cassette should be inserted, ribbon should be rotated correctly, make sure the sensor output. t) OHP sensor/luminance quantity adjustment (CN5-15, 21) Function : This is a transmission type sensor that detects paper kind after feeding paper. Pair LED luminance is set to obtain the most suitable luminance quantity. When reading ribbon code every time, the threshold level value for judging L or H is changed to the most suitable value. Level : Ordinary paper is H, OHP is L. Check method : Make sure the threshold level, transmit the paper, and make sure sensor the output. u) Head thermistor (CN7-27) Function : This thermistor measures temperature of the thermal head. Level : Approximately 2.5V at the normal temperature (25�C) Check method : Measure the voltage of thermistor. v) Room thermistor (CN4-17) Function : This thermistor measures the temperature at the inside of the unit. Level : Approximately 2.5V at the normal temperature (25�C) Check method : Measure the voltage of thermistor.
4-10
UP-D70/D70A (UC,CE)
|
|
 |
> |
|