|
Who's Online
There currently are 5840 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
This is a great site. I placed my order and by the next am it was available for download. Had some problems with some missing copy on some pages. Once I brought the error to the OMC's attention, the issue was resolved. I'll come back again.
;
Mi spiace per non poter scrivere in inglese... ma sono veramente soddisfatto del servizio offerto. Grazie..!!
;
The quality of this manual is good. It has all schematics and setup information for both the MDS-B3 and the MDS-B4. The scan quality is quite good, all pages are readable, This service manual also contains scans of the operating instructions from the User manual.
;
Quick site processing. A complete and very useful manual with all details. Thank you!
;
Das Service Manual war von der ersten bis zur letzten Seite sehr informativ und hilfreich. Die Darstellung aller Teile war klar und der Text gut lesbar.
Vielen Dank, das war nicht der letzte Download bei ownner-manuals.com.
s) Ribbon code sensor/luminance quantity adjustment (CN5-3, 19) Function : This is a transmission type sensor that reads ribbon code and starting mark on the ink ribbon. Pair LED luminance is set to obtain the most suitable luminance quantity. When reading ribbon code every time, the threshold level value for judging L or H is changed to the most suitable value. Level : Ribbon code portion is H, others are L Check method : Make sure the threshold level, ribbon cassette should be inserted, ribbon should be rotated correctly, make sure the sensor output. t) OHP sensor/luminance quantity adjustment (CN5-15, 21) Function : This is a transmission type sensor that detects paper kind after feeding paper. Pair LED luminance is set to obtain the most suitable luminance quantity. When reading ribbon code every time, the threshold level value for judging L or H is changed to the most suitable value. Level : Ordinary paper is H, OHP is L. Check method : Make sure the threshold level, transmit the paper, and make sure sensor the output. u) Head thermistor (CN7-27) Function : This thermistor measures temperature of the thermal head. Level : Approximately 2.5V at the normal temperature (25�C) Check method : Measure the voltage of thermistor. v) Room thermistor (CN4-17) Function : This thermistor measures the temperature at the inside of the unit. Level : Approximately 2.5V at the normal temperature (25�C) Check method : Measure the voltage of thermistor.
4-10
UP-D70/D70A (UC,CE)
|
|
|
> |
|