|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This was an excellent source of detailed assembly information on a device which is at least 12 years old. A very lucky find, coupled with great service.
 ;
Excellent Service Manual and best price on the Internet. This Service Manual covers everything you could ever need including full circuit schematics, component layout diagrams, stripdown procedure and full parts list/breakdown. I needed this to carry out a modification to one of these headunits and this manual covered everything I needed. Fast delivery, processed within a few hours.
 ;
Thought I would never find a copy of the Technics SX-EN2 Service Manual until I found Owner-Manuals.com. Price was very fair and I received the download promptly. While a photocopy, it is quite readable and includes all the pertinent information and diagrams. Thank you Owner-Manuals!
 ;
I really like this manual and it's reliable.I found and bought easly.thank you.
 ;
Thank you very much. the Instruction corresponds to my expectations. Sent it in time. I don't regret that paid money.
OSHIBA V 226B
Electrical Adjustments Cont�d
2-2. Audio Circuit The data displayed are as follows: Abnormality generation number
2
Wiring Diagram
www.u-view.co.uk
Abnormal system control modes
Main PC Board 2-2-1. Bias Level Adjustment Test Point: BS001, BS002 Test equipment: Millivoltmeter Adjusting point: PS034 1. Set the VTR to record mode. 2. Connect BS001 to the millivoitmeter and B5002 to GND. 3. Adjust PS034 to obtain 3.6 ± 0.1 mV(rms). 2-3. Self Diagnosis Function 2-3-1. Outline When a tape running stops or the VTR enters the power OFF mode, etc. due to some abnormality, the abnormality is stored in the EEPROM and displayed on the display tube. 2-3-2. Storing abnormal modes � The abnormality is classed into 5 groups, and the abnormality number, system control mode, and the mechanism position at which the abnormality occurred are stored in the EEPROM. � The writing timing is just after the abnormality occurred. 2-3-3. Abnormality mode display � Press the CH UP and CH DOWN buttons on the VTR simultaneously for more than 5s. � And then within 2s, press the STILL button on the remote control. � The system control mode at which the abnormality occurred is displayed at the channel display area, �E� is displayed at the hour digit, abnormality generation number is displayed at the minute digit, and the mechanism position is displayed in the second digit position. � The abnormality mode is displayed regardless of the power on off. Positions 0, 2, 4 exist as mechanism positions. For example, 8 shows a position between 7 and 9 (between playback position and review position).
Abnormal mechanism positions
� When the Counter Reset button is pressed in the display period, the abnormality display data is initialized and �-� is displayed.
|
|
 |
> |
|