Who's Online
There currently are 5895 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
I am proud of you. In the future, I benefited from your services.
;
I found this manual to be complete in every detail. Besides the schematic it has a complete set of alignment instructions which are easy to understand. It also includes a complete parts list as well as an explanation of how the power supply and safety shutdown circuits operate. Even a schematic of the tuner is included.
;
The product was good and just what I needed, however I had moderate difficulty with the down load because the sight would not recognize my pass word. I was finally given a direct link to the manual and that worked.
;
Very quick and easy website to use and fast download of manual, quality of manual is excellent and will be pleased to use this service again in the future, thanks so much!
;
It is an very good and clear scanned service manual.
very recommended.
OSHIBA V 226B
Electrical Adjustments Cont�d
2-2. Audio Circuit The data displayed are as follows: Abnormality generation number
2
Wiring Diagram
www.u-view.co.uk
Abnormal system control modes
Main PC Board 2-2-1. Bias Level Adjustment Test Point: BS001, BS002 Test equipment: Millivoltmeter Adjusting point: PS034 1. Set the VTR to record mode. 2. Connect BS001 to the millivoitmeter and B5002 to GND. 3. Adjust PS034 to obtain 3.6 ± 0.1 mV(rms). 2-3. Self Diagnosis Function 2-3-1. Outline When a tape running stops or the VTR enters the power OFF mode, etc. due to some abnormality, the abnormality is stored in the EEPROM and displayed on the display tube. 2-3-2. Storing abnormal modes � The abnormality is classed into 5 groups, and the abnormality number, system control mode, and the mechanism position at which the abnormality occurred are stored in the EEPROM. � The writing timing is just after the abnormality occurred. 2-3-3. Abnormality mode display � Press the CH UP and CH DOWN buttons on the VTR simultaneously for more than 5s. � And then within 2s, press the STILL button on the remote control. � The system control mode at which the abnormality occurred is displayed at the channel display area, �E� is displayed at the hour digit, abnormality generation number is displayed at the minute digit, and the mechanism position is displayed in the second digit position. � The abnormality mode is displayed regardless of the power on off. Positions 0, 2, 4 exist as mechanism positions. For example, 8 shows a position between 7 and 9 (between playback position and review position).
Abnormal mechanism positions
� When the Counter Reset button is pressed in the display period, the abnormality display data is initialized and �-� is displayed.
|
|
|
> |
|