Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is a good quality scan of the service manual which includes an assembly diagram, block diagram, schematic, and parts list. Exactly what is needed to repair my KR-V55R receiver.
 ;
Excellent concise manual. All needed information was included. Typeface and diagrams were clear. Very fair price considering what others are charging. Many thanks
 ;
Response is a little slow- I had to wait 12 hours to receive download link but it says that it may take up to 24hrs.
Manual is old and was not produced in PDF- scanned copy is exellent.
Overall- value for money- I recommend
 ;
Excellent quality and quickly delivered manuals at a fair price. Great care is taken in the reproduction process. Even photographs and highly detailed drawings are as clear as in the original. That cannot be said for some freelance manual copies I have obtained from the web. If you have exhausted your internet search of technical manuals, try Owner-Manuals.com. If they do not have it, I do not think it exists. Perhaps, if requested, they may be able to find it. Their resources are certainly greater than most. Shopping here certainly beats waiting for months or years for the manual you seek to appear in an internet auction or garage sale.
 ;
Very detailed product, also it is a scanning from original, very useful if you have to service this type of amplifier ! Very good product, very hard to find!
Alignment and Adjustment
5-3 Head Switching Point Adjustment
1) Playback the alignment tape. 2) Press the �SW703� button on Main PCB with pincers to set the adjustment mode. (See Fig. 5-2 ) 3) Press the �SP/LP� button of remote control then adjustment is operated automatically. (See Fig. 5-1) 4) Turn the Power off.
5-4 NVRAM Option Setting
1) NVRAM Option is adjusted at production line basically. 2) In case Micom (IC601) and NVRAM (IC605 ; EEPROM) is replaced, be sure to set the corresponding ooption number of the repaired model. (If the option is not set, the unit is not operated.) 1) Press the �SW703� button on Main PCB to set the adjustment mode. (See Fig. 5-2) 2) Press the �MENU� button on the remote control about 5 seconds then option setting display is appeared. (See Fig. 5-14) 3) Select the option number (See Table 5-2) of corresponding model with �CURSOR� button on the remote control. 4) If selecting the option number is completed, press the �OK� button of remote control. (If �OK� button is pressed, the selected number is changes reversed color. ; See Fig. 5-14) 5) Press the �MENU� button of remote control again to store the option number. (�PLEASE WAIT� is displayed for a second as shown Fig. 5-15 and this setting is completed.) 6) Turn the Power off.
01 09 17 25 33 41 49 57 65
02 10 18 26 34 42 50 58 66
03 04 05 06 07 08 11 12 13 14 15 16 19 20 21 22 23 24 27 28 29 30 31 32 35 36 37 38 39 40 43 44 45 46 47 48 51 52 53 54 55 56 59 60 61 62 63 64 67 68 69 70 71 72 CNG : OK SAVE : MENU
Fig. 5-14 <Table 5-2>
01 09 17 25 33 41 49 57 65
02 10 18 26 34 42 50 58 66
03 04 05 06 11 12 13 14 19 20 21 22 27 28 29 30 35 36 37 38 43 44 45 46 51 52 53 54 59 60 61 62 67 68 69 70 PLEASE WAIT
Fig. 5-15
07 15 23 31 39 47 55 63 71
08 16 24 32 40 48 56 64 72
MODEL V-621EW
OPTION NUMBER 6, 7, 8, 9, 10, 11, 13, 14, 15, 18, 20, 29, 30, 34, 35, 36, 38, 42, 45, 49, 50, 60, 61, 64
5-8