I found this manual to be complete in every detail. Besides the schematic it has a complete set of alignment instructions which are easy to understand. It also includes a complete parts list as well as an explanation of how the power supply and safety shutdown circuits operate. Even a schematic of the tuner is included.
 ;
The product was good and just what I needed, however I had moderate difficulty with the down load because the sight would not recognize my pass word. I was finally given a direct link to the manual and that worked.
 ;
Very quick and easy website to use and fast download of manual, quality of manual is excellent and will be pleased to use this service again in the future, thanks so much!
 ;
It is an very good and clear scanned service manual.
very recommended.
 ;
Easy to order the manual. Good quality and fast delivery.
Adjustment > Error Messages and Countermeasure
Error Messages
TOO BRIGHT PRESS ANY KEY TOO DARK PRESS ANY KEY 1) 2) 1) 2) 3)
Countermeasure
The subject is too bright. Move the camera further away from the light box. The subject is too dark. Check the light box. Move the camera closer to the light box.
When adjusting the auto focus
AF ERROR 1) If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. 2) Refer to �(4) No zoom and focus operation� on �4-1-2 Trouble Diagnosis Flowchart�. 1) Check the conditions of subject. 2) If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. 3) Refer to �(6) No focus lens operation� on �4-1-2 Trouble Diagnosis Flowchart�. 1) Check the conditions of subject. 2) If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. 3) Refer to �(4) No zoom and focus operation� on �4-1-2 Trouble Diagnosis Flowchart�. 1) If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. 2) Refer to �(7) No zoom operation� on �4-1-2 Trouble Diagnosis Flowchart�. 1) Insufficient lighting. Check the subject. 1) Supply power again and readjust.
AF LIMIT OVER
TIME OUT ERROR ON AF STEP
TIME OUT ERROR ON FOCUS
TIME OUT ERROR ON ZOOM
TOO DARK TRACE ERROR. ADJUST ZOOM TRACE & AF NOISE AGAIN ERROR!! SPOT NOISE COMPENSATION IS STOPPED BY INITIAL DATA. PLEASE CHECK THE EEPROM. PRESS ANY KEY. ERROR!! THE SPOT NOISE IS TOO MANY. CAN'T COMPENSATE ANY MORE. PRESS ANY KEY. ERROR!! THRESHOLD DATA ERROR. PLEASE CHECK THE EEPROM. PRESS ANY KEY.
When adjusting the spot noise
1) Spot noise compensation is inhibited by the data in the EEPROM. 2) Turn the power on again. 3) Data in the EEPROM is defective. (data Initialize it.) 4) Check the EEPROM, and if necessary, replace it. 1) The amount of spot noise that can be compensated reaches the limit. 2) Turn the power on again. 3) Check the image sensor, and if necessary, replace it. 1) Turn the power on again. 2) Data in the EEPROM is defective. (data Initialize it.) 3) Check the EEPROM, and if necessary, replace it.
6 - 15
|
|
 |
> |
|