Adjustment > Error Messages and Countermeasure
6-8 Error Messages and Countermeasure
A message may appear while you are adjusting the video camera. If a message appears, refer to the following table and take appropriate corrective action. Error Messages Countermeasure When adjusting the electric volume and adjustment
CAN'T ADJUST WHITE BALANCE PLEASE RETRY PRESS ANY KEY D RANGE OVER. ERROR ON da� ADJUSTMENT PRESS ANY KEY. (�: Error code) D RANGE OVER ERROR ON HALL AMP IRIS CANNOT OPEN ANY MORE PRESS ANY KEY 1) 2) 3) 4) 1) 2) The subject is too bright or too dark. Check the light box. Move the camera closer to or away from the light box. Supply power again and readjust. Check the values in the hall amp circuit. Defective soldering, damage to pattern, etc. in the above circuit.
1) 2) 3) 4) 5) 6) 1) 2) 3)
ERROR OCCURRED. IRIS TROUBLE PRESS ANY KEY
4) ERROR OCCURRED ON da� ADJUSTMENT 1) PRESS ANY KEY 2) ERROR OCCURRED ON da0 and da1 ADJUSTMENT PRESS ANY KEY FILE NOT FOUND !!!! PRESS ANY KEY FILE OPEN ERROR !!!! PRESS ANY KEY ERROR OCCURRED ON C DUTY ADJUSTMENT PRESS ANY KEY ERROR OCCURRED ON FDET ADJUSTMENT PRESS ANY KEY ERROR OCCURRED. ZOOM DOES NOT WORK PRESS ANY KEY STAURATION ERROR. TOO BRIGHT PRESS ANY KEY 1) 2) 1) 2) 1) 2) 1) 2) 1) 2) 3) 1)
Supply power again and readjust. The subject is too dark. Check the light box. Move the camera closer to the light box. Check the values in the hall amp circuit. Defective soldering, damage to pattern, etc. in the above circuit. Check whether or not power is supplied. Check the values of the iris drive circuit. Defective soldering, damage to pattern, etc. in the above circuit. Check the iris block and replace it if necessary. Check the values in the hall amp circuit. Defective soldering, damage to pattern, etc. in the above circuit. Check the values in the hall amp circuit and its peripheral circuits. Defective soldering, damage to pattern, etc. in the above circuits. The adjustment program (file) cannot be found. Check the adjustment floppy disk and replace it if necessary. The adjustment program (file) does not start. Check the adjustment floppy disk and replace it if necessary. Check the values of the iris drive circuit. Defective soldering, damage to pattern, etc. in the above circuit. Supply power again and readjust. Check the values in the hall amp circuit. Defective soldering, damage to pattern, etc. in the above circuit. Supply power again and readjust.
1) The subject is too bright. 2) Move the camera further away from the light box.