Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Perfect source for service manuals: fast and professional transaction; high quality, perfect readable and largely scaleable PDF; complete schemes, diagrams and spare part list. Tnx a lot, cu again!!!!
 ;
I got your link from a friend and I must say that I am really satisfied with your service. Specially this B&O manual I didn't find anywhere on the web... but you could deliver it :-) . You deliver very fast and the copy is of good quality. So your webpage is bookmarked. Thanks
 ;
This was the Sony CCU-500A Service manual I was looking for.
The price was reasonable.
The permission to download was quck.
I will use Owner-Manual.com for all my manual needs.
 ;
Excellent printing quality.
A complete and very usefull service manual with all details.
GREAT SERVICE AT VERY LOW PRICE!
A+++++++++++++++++++++++++
 ;
Excellent printing quality.
A complete and very usefull service manual with all details.
GREAT SERVICE AT VERY LOW PRICE!
A+++++++++++++++++++++++++
Adjustment > Error Messages and Countermeasure
Error Messages
TOO BRIGHT PRESS ANY KEY TOO DARK PRESS ANY KEY 1) 2) 1) 2) 3)
Countermeasure
The subject is too bright. Move the camera further away from the light box. The subject is too dark. Check the light box. Move the camera closer to the light box.
When adjusting the auto focus
AF ERROR 1) If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. 2) Refer to �(4) No zoom and focus operation� on �4-1-2 Trouble Diagnosis Flowchart�. 1) Check the conditions of subject. 2) If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. 3) Refer to �(6) No focus lens operation� on �4-1-2 Trouble Diagnosis Flowchart�. 1) Check the conditions of subject. 2) If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. 3) Refer to �(4) No zoom and focus operation� on �4-1-2 Trouble Diagnosis Flowchart�. 1) If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. 2) Refer to �(7) No zoom operation� on �4-1-2 Trouble Diagnosis Flowchart�. 1) Insufficient lighting. Check the subject. 1) Supply power again and readjust.
AF LIMIT OVER
TIME OUT ERROR ON AF STEP
TIME OUT ERROR ON FOCUS
TIME OUT ERROR ON ZOOM
TOO DARK TRACE ERROR. ADJUST ZOOM TRACE & AF NOISE AGAIN ERROR!! SPOT NOISE COMPENSATION IS STOPPED BY INITIAL DATA. PLEASE CHECK THE EEPROM. PRESS ANY KEY. ERROR!! THE SPOT NOISE IS TOO MANY. CAN'T COMPENSATE ANY MORE. PRESS ANY KEY. ERROR!! THRESHOLD DATA ERROR. PLEASE CHECK THE EEPROM. PRESS ANY KEY.
When adjusting the spot noise
1) Spot noise compensation is inhibited by the data in the EEPROM. 2) Turn the power on again. 3) Data in the EEPROM is defective. (data Initialize it.) 4) Check the EEPROM, and if necessary, replace it. 1) The amount of spot noise that can be compensated reaches the limit. 2) Turn the power on again. 3) Check the image sensor, and if necessary, replace it. 1) Turn the power on again. 2) Data in the EEPROM is defective. (data Initialize it.) 3) Check the EEPROM, and if necessary, replace it.