I bought the service-manual of the sony ICB-1020(an old transmitter-receiver) at "www.Owners-Manual.com", I found the service-manual for a fairly cheap price(in comparison with other sellers). I filled in some questions, payed the order with Ideal, and within 24 hours I had my service manual. I was very happy:In no time I had my service-manual and everything, but literally everything was noted down in the manual; the electronic scheme, the parts list, etcetera.
A very practical, reference-document.
;
This comprehesive service maual was greatly appreciated, as was the digital download.
;
Good en helpfull black and white scanned Srfvice manual of the Philps D8444. Quick service and delivery
6.2 Error Message of Autofocus
ERROR MESSAGE ERROR OCCURRED. ZOOM DOES NOT WORK PRESS ANY KEY TIME OUT ERROR ON FOCUS COUNTERMEASURE Supply power again and re-adjust. Check the conditions of subject. If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. Refer to (1) of TROUBLESHOOTING OF AUTOFOCUS. If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. Refer to (2) of TROUBLESHOOTING OF AUTOFOCUS. Check the conditions of subject. If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. Refer to (1) of TROUBLESHOOTING OF AUTOFOCUS. Check the conditions of subject. If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. Refer to (2) of TROUBLESHOOTING OF AUTOFOCUS. If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. Refer to (1) of TROUBLESHOOTING OF AUTOFOCUS. Insufficient lighting. Check the subject.
TIME OUT ERROR ON ZOOM
TIME OUT ERROR ON AF STEP
AF LIMIT OVER
AF ERROR
TOO DARK
6.3 Error Message of Spot Noise Adjustment
ERROR MESSAGE ERROR!! SPOT NOISE COMPENSATION IS STOPPED BY INITIAL DATA. PLEASE CHECK THE EEPROM. PRESS ANY KEY. ERROR!! THRESHOLD DATA ERROR. PLEASE CHECK THE EEPROM. PRESS ANY KEY. ERROR!! THE SPOT NOISE IS TOO MANY. CAN'T COMPENSATE ANY MORE. PRESS ANY KEY. COUNTERMEASURE Spot noise compensation is inhibited by the data in the EEPROM. Turn the power on again. Data in the EEPROM is defective. (Initialize it.) Check the EEPROM, and if necessary, replace it. Turn the power on again. Data in the EEPROM is defective. (Initialize it.) Check the EEPROM, and if necessary, replace it. The amount of spot noise that can be compensated reaches the limit. Turn the power on again. Check the CCD image sensor, and if necessary, replace it.
6.4 Error Message of IR Control
ERROR MESSAGE IR ERROR COUNTERMEASURE If this error message appears even when the adjustment is performed 2 or 3 times, the IR control circuit system is defective. Refer to TROUBLESHOOTING OF IR CONTROL.