Very good documentation for the Grundig 2077 model (as well as similar 800/900/1000 series radios). The first two pages are a summary of reception specifications and output capability. The third page is the tuner dial indicator and dial cord routing diagram. the final ~5 pages are the schematics for the various models (including 2077). The scan quality of the schematics are good, adn can be easily read if zoomed in. The documents are in German, not English as stated. It would have been nice to have the tuning sequence and settings, and some trouble shooting materials... or component and wiring map.
 ;
Perfect like it was descriped, Perfect like it was descriped
 ;
Very good detail, all pages clear, exactly what I needed
6.2 Error Message of Autofocus
ERROR MESSAGE ERROR OCCURRED. ZOOM DOES NOT WORK PRESS ANY KEY TIME OUT ERROR ON FOCUS COUNTERMEASURE Supply power again and re-adjust. Check the conditions of subject. If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. Refer to (1) of TROUBLESHOOTING OF AUTOFOCUS. If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. Refer to (2) of TROUBLESHOOTING OF AUTOFOCUS. Check the conditions of subject. If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. Refer to (1) of TROUBLESHOOTING OF AUTOFOCUS. Check the conditions of subject. If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. Refer to (2) of TROUBLESHOOTING OF AUTOFOCUS. If this error message appears even when the adjustment is performed 2 or 3 times, the autofocus circuit system is defective. Refer to (1) of TROUBLESHOOTING OF AUTOFOCUS. Insufficient lighting. Check the subject.
TIME OUT ERROR ON ZOOM
TIME OUT ERROR ON AF STEP
AF LIMIT OVER
AF ERROR
TOO DARK
6.3 Error Message of Spot Noise Adjustment
ERROR MESSAGE ERROR!! SPOT NOISE COMPENSATION IS STOPPED BY INITIAL DATA. PLEASE CHECK THE EEPROM. PRESS ANY KEY. ERROR!! THRESHOLD DATA ERROR. PLEASE CHECK THE EEPROM. PRESS ANY KEY. ERROR!! THE SPOT NOISE IS TOO MANY. CAN'T COMPENSATE ANY MORE. PRESS ANY KEY. COUNTERMEASURE Spot noise compensation is inhibited by the data in the EEPROM. Turn the power on again. Data in the EEPROM is defective. (Initialize it.) Check the EEPROM, and if necessary, replace it. Turn the power on again. Data in the EEPROM is defective. (Initialize it.) Check the EEPROM, and if necessary, replace it. The amount of spot noise that can be compensated reaches the limit. Turn the power on again. Check the CCD image sensor, and if necessary, replace it.
6.4 Error Message of IR Control
ERROR MESSAGE IR ERROR COUNTERMEASURE If this error message appears even when the adjustment is performed 2 or 3 times, the IR control circuit system is defective. Refer to TROUBLESHOOTING OF IR CONTROL.