Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I was having a hard time finding the problem with this Mackie 1604 unit. I didn't have a schematic. Went looking on the web and found your site and the price was more then reasonable. Ordered it and within the hour had the manual and within 15 minutes had the unit fixed. Best $4.99 I ever spent. Thank you.
Doug
 ;
This is a service manual in every sense of the word ( French and German versions of the text are included, as well as English..)
There are explanations of the mechanical and electrical functions, plenty of mechanical drawings, and the needed schematics. The quality of the scanning is excellent - all the component values are clearly legible - and very usefully there are pcb component layouts, so you can find a component on the schematic, and then very quicky pinpoint its physical location on the relevant pcb.
I cannot see how I can give this manual any less than the maximum 5 stars! Great value for money, which will pay for itself immediately. Excellent all round!
 ;
the manual is great and especially hard to find... thanks for the great service and having a hard to find manuel_
 ;
Please tell us what you think and share your opinions with others. Be sure to focus your comments on the product. You will receive $2.50 of store credit for Your review.
 ;
hat alles sehr gut geklappt. Das Servicemaual ist gut zu verwenden. Die Pläne und Schrift
ist klar und leserlich. Außerdem preiswert. Grüße an alle Hifi-Bastler
VL-AH150U VL-AH160U
Claw C Claw B View E Claw A Claw D View F
Note: When fixing the cassette compartment lid, first engage the claws A and B, and then engage the claws C and D, verify that the four claws (A, B, C and D) of the cassette compartment lid are securely engaged as shown in the view above. <11. Disassembly of the LCD panel>
(2)
(1)
Claw (A) Reflection sheet Light guide plate Diffusion sheet Lugs Prism sheet Lugs
Claw (A)
(3) Claw (B) Disengage the claw, and remove the LCD panel. (C) (2)
(4) FPC
Arm(E)
Arm(D)
1. Disengage two claws (A), and remove the lamp inverter unit (1) from the LCD holder (2). 2. Remove the sheets from the LCD holder (2). 3. Pull the LCD glass retaining (3). 4. Remove the FPC from Arm(D) and (E). 5. Disengage the claw (B), and slide the LCD panel (4) in the (C) direction to remove the LCD holder (2). Note: When handling the prism sheet, diffusion sheet, light guide plate and, reflection sheet do not touch any parts other than lugs and sides. Put the light guide plate and reflection sheet between reflectors of lamp. Therefore, install them together with the lamp ass'y.