|
Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
Thank you very much. the Instruction corresponds to my expectations. Sent it in time. I don't regret that paid money.
 ;
Good quality. Quick service. I recommend to everyone.
 ;
Very good quality scan of the document. I am very pleased with what I got.
 ;
PDF Contains
Technical Data, Mechanical data, Detailed Circuit diagram with components value, PCB layout. Actual PCBs Print. Component List, Spare parts code list and Input output detail. It cover LBB1211, LBB1212, LBB1213, LBB1216, LBB1217.
It is the actual Service Manual for SQ10
 ;
very good manual with clear electrical schemes. Very helpful to find wat was wrong inside my microwave.
4.
ERROR MESSAGE
A message may appear while you are adjusting the video camera/recorder. If a message appears, refer to the following table and take appropriate corrective action.
4.1 Digital Adjustments
ERROR MESSAGE ERROR OCCURRED. IRIS TROUBLE PRESS ANY KEY COUNTERMEASURE Check whether or not power is supplied. Check the values of the iris drive circuit. Defective soldering, damage to pattern, etc. in the above circuit. Check the iris block and replace it if necessary. Check the values in the hall amp circuit. Defective soldering, damage to pattern, etc. in the above circuit. Check the values in the hall amp circuit. Defective soldering, damage to pattern, etc. in theabove circuit. Check the values in the hall amp circuit and its peripheral circuits. Defective soldering, damage to pattern, etc. in the above circuits. The adjustment program (file) cannot be found. Check the adjustment floppy disk and replace it if necessary. The adjustment program (file) does not start. Check the adjustment floppy disk and replace it if necessary. Check the values of the iris drive circuit. Defective soldering, damage to pattern, etc. in the above circuit. Supply power again and re-adjust. Check the values in the hall amp circuit. Defective soldering, damage to pattern, etc. in the above circuit. Supply power again and re-adjust. The subject is too bright. Move the camera further away from the light box. The subject is too dark. Check the light box. Move the camera closer to the light box. Supply power again and re-adjust. The subject is too dark. Check the light box. Move the camera closer to the light box. Check the values in the hall amp circuit. Defective soldering, damage to pattern, etc. in the above circuit. The subject is too bright. Move the camera further away from the light box. The subject is too bright or too dark. Check the light box. Move the camera closer to or away from the light box. Supply power again and re-adjust.
ERROR OCCURRED ON da� ADJUSTMENT PRESS ANY KEY D RANGE OVER. ERROR ON da� ADJUSTMENT PRESS ANY KEY. ERROR OCCURRED ON da0 and da1 ADJUSTMENT PRESS ANY KEY FILE NOT FOUND !!!! PRESS ANY KEY FILE OPEN ERROR !!!! PRESS ANY KEY ERROR OCCURRED ON C DUTY ADJUSTMENT PRESS ANY KEY ERROR OCCURRED ON FDET ADJUSTMENT PRESS ANY KEY ERROR OCCURRED. ZOOM DOES NOT WORK PRESS ANY KEY TOO BRIGHT PRESS ANY KEY TOO DARK PRESS ANY KEY D RANGE OVER ERROR ON HALL AMP IRIS CANNOT OPEN ANY MORE PRESS ANY KEY
STAURATION ERROR. TOO BRIGHT PRESS ANY KEY CAN'T ADJUST WHITE BALANCE PLEASE RETRY PRESS ANY KEY
3 - 12
|
|
 |
> |
|