|
Categories
|
Information
|
Featured Product
|
|
|
 |
|
There are currently no product reviews.
 ;
It is pretty good. The schematics were covered all components, the manual also provide the parts list . It's useful for the trouble shooting.
 ;
Very fast service, best quality of the service manual and the schematics
 ;
This service manual of the old video cassette recorder VT-LC50EM is very good readable even the tiniest numbers (i.e. IC-pins). The circuits are very clear. Many details of the schematic are very good described but in GERMAN language. Many schematic details - but complete at all. Common background information of several details are enclosed and physical knowledge of the TFT liquid crystal display for example. The manual lacks PCB drawings. If you understand german I would recommend this manual for you.
 ;
Hi, this is a very clear manual, nice copy, not quite up to the standard of the very best available but better than many others. I think the price was especially fair for a hard to find manual and I would certainly use this manual seller again. Recommended.
 ;
This schema available for me in good condition. I would highly recommend.
MATSUI VP 9405
Matrix
Item See Model Book
6 6 6 Deck Exploded View ............................................................................ VXA 1105 Deck Alignment .................................................................................... VXA 1105 Deck Adjustments ................................................................................ VXA 1105
1
Head Amp Diagram
Electrical Adjustments
3. ADJUSTMENT PROCEDURE Read and perform these adjustments when repairing the circuits or replacing electrical parts or PCB assemblies. CAUTION When replacing IC�s or transistors, use only specified silicon grease (YG6260M). (To prevent the damage to IC�s and transistors.) 3-1: PG SHIFTER CONDITIONS MODE-PLAYBACK Input Signal-Alignment Tape (JG001C) INSTRUCTIONS 1. Playback the alignment tape. (JG001C) 2. Press both Tracking AUTO key on the Customer remote control and the PLAY button on the set simultaneously until the indicator ATR disappear�s. If the indicator ATR disappear�s, the adjustment is finished. (If the ATR indicator is still illuminated) 1. Connect CH-1 on the oscilloscope to TP4001 and CH-2 to Pin 19 of J4501. 2. Press the PG AUTO key. (JG155) 3. While the ATR indicator is flashing, press the PG MANUAL key. (JG155) 4. Adjust the Tracking +/- key until waveform of the oscilloscope measures 6.5 ± 0.5(H) at both leading and trailing edges. (Refer to Fig. 3-1-A, B) 5. Press the Tracking Auto key.
Fig. 3-1-A
Fig. 3-1 -B
|
|
 |
> |
|
|
Parse Time: 0.327 - Number of Queries: 137 - Query Time: 0.071