Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Well.. I'd searched for this manual and although I found many copies online I was pleased to find your website with a well balanced pricing system and easy to search and follow links. That together with the very quick response time was just what I was looking for.. being a very impatient tech.. ;-) I had the service manual in front of me within a short time.
Bookmarked.. and you can bet I will always come here first for my service & user manuals..
best regards
Ed(Tony) Foley
G7WHK
 ;
I will definitely be back for more information when I need it.
 ;
The service manual when downloaded and printed out was clear and easy to read. I would have liked to have been able to enlarge some details, but this was not possible as the file permissions did not allow this. The service was very good. The time taken from placing my order to downloading the document was only a few minutes.
 ;
The manual is useful for trouble shooting for an old instrument. It saved money,and let me enjoy DIY.
 ;
Perfect source of information for replacing the HDD and performing general diagnostics.
Alignment and Adjustment
5. AUTO IRIS 1) Camera �E-E�, 3100°K gray-scale chart. 2) Video(output) jack and AF MICOM. 3) Connect video(output) jack to waveform monitor input jack and monitor TV jack respectively. 4) Press the �DATE/TIME(MODE UP)/ TITLE (MODE DOWN)� button so that the OSD state is �OCE. IRIS XX XX�. 5) Press �MENU/ENTER(CONFIRM)� Button. 6) Then, the micro process will work; - IRIS open, IRIS control MAXIMUM Value found. - IRIS close, IRIS control minimum Value found. - Store the MIN/MAX data to mode 0BE, 0BF and mode 0A3, 0A4. 7) The OSD shows �O.K�.
Center of white level H
b-2. Press �MENU/ENTER(CONFIRM)� button so that the white vector moves to the center on screen of the vectorscope. b-3. During the control W/B outdoor, OSD shows �0CF, AWB xx 01�. The OSD shows �OK!�. b-4. Store the data to mode 053, 054, 055 and 056.
Match the white luminance point with the black luminance point
100IRE
Match the white luminance point with the black luminance point
Optical black level
40US
6. Auto white balance 1) Camera �E-E�, 3100°K/5100°K gray-scale chart. 2) Video(output) jack and AF MICOM. 4) Connect vectorscope input jack to video(output) jack. 3) Press the �DATE/TIME(MODE UP)/TITLE (MODE DOWN)� button so that the OSD state is �OCF. AWB XX XX�. a. W/B Indoor a-1. Aim the camera at a 3100°K gray-scale chart illuminated at 1500 to 2000 lx. (40us) a-2. Press �MENU/ENTER(CONFIRM)� button so that the white vector moves to the center on screen of the vectorscope. a-3. During the control W/B indoor, OSD shows �0CF, AWB xx 00�. The OSD shows �OK!�. b. W/B Outdoor b-1. Aim the camera at a 5100°K gray-scale (or, 3100°K+C16 filter) chart illuminated at 1500 to 2000 lx. (40us)
7. Pre white balance (I) 1) Camera �E-E�, 3100°K gray-scale chart. 2) Video(output) jack and AF MICOM. 3) Connect vectorscope input jack to video(output) jack. 4) Press the �DATE/TIME(MODE UP)/TITLE (MODE DOWN)� button so that the OSD state is �137. XX XX.� (R-Y axial) 5) Aim the camera at a 3100°K gray-scale chart illuminated at 1500 to 2000 lx. 6) Adjust the �C/RESET(DATA UP)/Z/RTN (DATA DOWN)� button so that the white vector moves to the R-Y axial on screen of the vectorscope. Note : Bright dot shifts after the confirm button is pressed.