Probably it never existed a 1081 official service manual from Commodore, it's look more like a NAPCEC service manual & diagrams compilation of the 1084 series and his variants, like the nap6523, 8cm505, 1084S, 1084P and obviously the 1081. It's more complete than other scans and the quality of the scans also are far superior. It has two circuit diagrams variants of the 1081, mono and stereo versions. It doesn't include a diagram for the Philips CM8500 or CM8501, they look like the 1081 but they are slightly different.
 ;
Rapid, clear well done as all the scheme I downloaded from this site. Great job very functional and very useful
3. AWB Adjustment
4. CCD White Point Defect Detect Adjustment
Preparation: POWER switch: ON Adjustment method: 1. Double-click on the DscCalDi.exe. 2. Select �CCD Defect� on the LCD �Test�, and click the �Yes�. 3. After the adjustment is completed, OK will display. 4. Click the OK.
5. CCD Black Point And White Point Defect Detect Adjustment In Lighted
Camera
Pattern box (color viewer)
Preparation: POWER switch: ON Adjusting method: 1. When setting the camera in place, set it to an angle so that nothing appears in any part of the color viewer except the white section. (Do not enter any light.) 2. Double-click on the DscCalDi.exe. 3. Click the AWB, and click the Yes. 4. AWB adjustment value will appear on the screen. 5. Click the OK.
Dsc Calibration AWB Result: 1: AGC=220,388,481,724,892 3F_AGC=0,0 WB=237,511,501 CHECK=128,128,140 MS=3472,3565 0 IRIS=179 OK Copy
Camera
Pattern box (color viewer)
x
Preparation: POWER switch: ON Setting of pattern box: Color temperature: 3100 ± 20 (K) Luminance: 900 ± 20 (cd/m2) Adjusting method: 1. Set the camera 0 cm from the pattern box. (Do not enter any light.) 2. Double-click on the DscCalDi.exe. 3. Select �CCD Black� on the LCD �Test�, and click the �Yes�. 4. After the adjustment is completed, the number of defect will appear.
Adjustment value determination is effectuated using the "AGC", �CHECK" and "MS" values. If AGC=a1, a2, a3, a4, a5, CHECK=wc0, wc1, wc2 and MS=MS1, MS2, the adjustment values fulfill the conditions below, they are determined as within specifications. Adjustment value determination 150<a1<350, 330<a2<540, 450<a3<680, 600<a4<850, 800<a5<1024 wc0=128 ± 2, wc1=128 ± 2, wc2=130 ± 40 2500<=MS1<=4500 2900<=MS2<=5200 150<IRIS<220 Adjustment values other than the above are irrelevant. � 15 �
|
|
 |
> |
|