Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I searched EVERYWHERE looking for the manual/s on this "extinct" amp. Owner-Manuals.com made it available and for nearly nothing. Thanx to them, I can decipher the unknown cables and sort them out. Thanx, Owner-Manuals.com!!
 ;
Yes thank you i got the file i was after. There was a slight problem in my communication but it all worked out well.
A job well done.
 ;
Great manual...really saved me. The only problem is that I thought I would be able to download it directly when I paid for it but never received the download instructions until the next morning. The board trace pages were somewhat light also: really need to turn up the contrast on the printer before printing them. The schematic page was great; very clear! Well worth the money.
 ;
I've been in the electronic business for a long time. I used to buy Sam's Photofact for my needs which intailed having to go to the store and paying about $20 for a package of 3 different units so I was forced to buy more than I needed just to get one.
Owner manual is just at your keyboard and the information is almost instantansouly and the cost is very reasonable. Easy to print out if needed or simply read off of the screen. The larger the screen the better for obvious reasons.
 ;
Very good manual, at a very good price. Received in a timely manner
Notes on Installation
Carry out the followings.
Maintenance
Maintenance
Note on the Time to Replace the Lamp
When it is time to replace the lamp, replace the lamp promptly with a new LMP-600 Projector Lamp.
For details on replacement, refer to the instruction manual supplied with the LMP-600 Projector Lamp.
Cleaning the Air Filter
The air filter should be cleaned every 300 hours. When it becomes difficult to remove the dust from the filter, replace the filter with a new one. To clean the air filter, follow the steps below:
No toppling of the unit
Avoid using as the unit topples over on its side. It may cause malfunction.
1 2
Turn off the power and unplug the power cord. Remove the air filter cover on the bottom of the projector.
Use to be level
Avoid using as the unit titles more than 20 degrees. Do not install the unit other than on the floor or ceiling. These installation may cause malfunction.
20°
20°
20°
3
20° 20°
Remove the air filter.
No blocking the ventilation holes
Avoid using something to cover over the front ventilation holes; otherwise, the internal heat may build up. Use the supplied front cover only when the power is turned off. Do not turn on the projector with the front cover on. It may cause malfunction.
4 5
Remove the dust from the filter with a vacuum cleaner. Attach the air filter and replace the cover.
Notes
� If the air filter is excessively dirty, wash it with a mild detergent solution and dry it in a shaded place. If the dust cannot be removed, replace the air filter with the supplied new one. � Be sure to attach the air filter cover firmly; the power will not be turned on if it is not closed securely.
36 (EN)
37 (EN)
1-19 VPL-S600
|
|
 |
> |
|