Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I was having a hard time finding the problem with this Mackie 1604 unit. I didn't have a schematic. Went looking on the web and found your site and the price was more then reasonable. Ordered it and within the hour had the manual and within 15 minutes had the unit fixed. Best $4.99 I ever spent. Thank you.
Doug
 ;
This is a service manual in every sense of the word ( French and German versions of the text are included, as well as English..)
There are explanations of the mechanical and electrical functions, plenty of mechanical drawings, and the needed schematics. The quality of the scanning is excellent - all the component values are clearly legible - and very usefully there are pcb component layouts, so you can find a component on the schematic, and then very quicky pinpoint its physical location on the relevant pcb.
I cannot see how I can give this manual any less than the maximum 5 stars! Great value for money, which will pay for itself immediately. Excellent all round!
 ;
the manual is great and especially hard to find... thanks for the great service and having a hard to find manuel_
 ;
Please tell us what you think and share your opinions with others. Be sure to focus your comments on the product. You will receive $2.50 of store credit for Your review.
 ;
hat alles sehr gut geklappt. Das Servicemaual ist gut zu verwenden. Die Pläne und Schrift
ist klar und leserlich. Außerdem preiswert. Grüße an alle Hifi-Bastler
1
2
3
4
7.1.3 HOW TO DIAGNOSE THE UNIT WITH THE POWER AMPLIFIER SECTION REMOVED
Purpose:
A
When repairing this unit, the large Heat Sink Block obstructs access to some Assys. If the Heat Sink Block is removed, as the posistor mounted on it is also disconnected, the protection circuit is activated, which disables failure diagnosis of these Assys while the unit is powered. With the method explained here, the Assys that cannot be diagnosed while the unit is powered because of the Heat Sink Block can be diagnosed by creating an artificial status of the posistor's being connected (by connecting a 100-ohm resistor under normal temperature). Note: Use this method for diagnosing a failure other than possible failures inside the Heat Sink Block, such as those shown in the table below: Symptoms that are highly suspected to be failures inside the Heat Sink Block
1 No power with the MCACC LED flashing
Possible causes
DC detection has been activated to prevent further damage to the unit. Note: Refer to "7.1.2 How to diagnose the Amplifier Section" in the service manual. The peripheral circuits of the posistor inside the Power Amplifier Section are in failure. Note: A posistor is a kind of thermistor, and its resistance is approx. 100 ohms at normal room temperature.
B
2 The unit turns itself off after "AMP ERR" was displayed on the FL display. Then it goes into state 1 above. 3 "OVERHEAT" is displayed on the FL display under normal temperature, then the unit turns itself off. 4 The unit turns itself off without any indication on the FL
Overloaded amplifier, failure in the overload-detection circuit inside the Power Amplifier Section, etc. 5 "FAN STOP" is displayed on the FL display, then the unit turns Disconnection of the Fan connector, failure in the fan. (Only for the itself off. models for Europe and those for other than North America and Japan)
C
Procedures:
1 Remove the bonnet and center beam. 2 Remove all the wires from the wire saddle. 3 Disconnect all six connectors connected between the Amplifier Assy and the SP/PS Assy.
� Remove the wires.
3
D
2
� Disconnect the parallel wires.
4 Disconnect the parallel wires from the connector CN2201. (If the wires are not easily disconnected, disconnect them with the connector attached, using a vacuum desoldering tool.)
E
5 Remove the eight screws that secure the Amplifier section.
4
F
TRANS 2-1 Assy
114
1 2
VSX-1015TX-K
3 4
|
|
 |
> |
|