Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
I'm very satisfied with your manual service. Your website made it easy to locate the correct manual. Also the quality is great and I never had a problem reading the fine details.
Thanks again.
Jeff Miller
JM Electronics
 ;
Good quality service manual German user manual. German user manual This is a quality scan of a manual in excellent condition and is just as good as having the original manual in hand
 ;
The manual for Sony LBT-D505 component stereo system is was excellent , with schematics, parts layout and parts list as well as instructions for adjustments for each component. Print was clear even when enlarged.
 ;
It's exactly a complete and very useful manual with all details what I needed. Thank you!I will come back whenever I need your manuals or schematics.
 ;
I searched EVERYWHERE looking for the manual/s on this "extinct" amp. Owner-Manuals.com made it available and for nearly nothing. Thanx to them, I can decipher the unknown cables and sort them out. Thanx, Owner-Manuals.com!!
5
6
7
8
A Step 2-3: Input selection Step 2-5: SDA/SCL
CN1001 (Pin 5) Is the voltage "L" when selecting IN1? And is the voltage "H"(5V) when selecting IN2? Yes CN1001 (Pin 4) SELB SELA IC102 (Pin 7) No Diagnose the MAIN Assy. Does a signal output in constant period (0 to 5 V) ? Yes IC102 (Pin 9) SDA (HDMI OUT)
A
No Check the JA301 and IC102. If JA301 or IC102 is failure, replace JA301 or IC102.
SCL (HDMI OUT)
B
Is the voltage "H"(5V) when selecting IN1? And is the voltage "L" when selecting IN2? Yes
No Diagnose the MAIN Assy.
Does a clock output in constant period (0 to 5 V) ? Yes IC101 (Pin 39) Is there a same signal as IC102-pin 7 (0 to 3.3V) ? Yes IC101 (Pin 38)
No Check the JA301 and IC102. If JA301 or IC102 is failure, replace JA301 or IC102.
SDA_SINK
Step 2-4: Hot Plug Detect
CN1001 (Pin 7) HPD_IN
No Check the IC102 and IC101. If IC102 or IC101 is failure, replace IC102 or IC101.
C
Is the voltage "H" (5 V)? Yes CN1001 (Pin 6)
No Check the JA301. If JA301 is failure, replace JA301.
SCL_SINK
HPD_SINK
Is the voltage "H" (5 V)?
No Diagnose the MAIN Assy.
Is there a same No Check the IC102 and IC101. signal as IC102-pin 9 If IC102 or IC101 is failure, (0 to 3.3V) replace IC102 or IC101. ? Yes * When connected the source equipment to IN1;
D
IC101 (Pin 63) Yes * When connected the source equipment to IN1; JA101 (Pin 19) Is the voltage 5 V when selecting IN1? HPD0 Check the IC101 and JA101. If IC101 or JA101 is failure, replace IC101 or JA101.
SDA (HDMI IN1)
No
Is there a same No Check the IC101 and JA101. signal as IC102-pin 7 If IC101 or JA101 is failure, when selecting replace IC101 or JA101. IN1? (0 to 5 V) Yes IC101 (Pin 64) SCL (HDMI IN1)
Yes * When connected the source equipment to IN2; JA102 (Pin 19) Is the voltage 5 V when selecting IN2? Yes HPD1
No
Check the IC101 and JA102. If IC101 or JA102 is failure, replace IC101 or JA102.
Is there a same No Check the IC101 and JA101. signal as IC102-pin 9 If IC101 or JA101 is failure, when selecting replace IC101 or JA101. IN1? (0 to 5 V) Yes
E
B