3. Board detection
A
If the board connection from Main Ass�y to Amp&Primary Ass�y is interrupted, the BOARD_DET port becomes �H�. If the �H� is detected, the microprocessor will perform as following flow chart. In the case of simultaneous detection with the overload protection circuit, Board detection is performed preferentially to DC-abnormality detection and Overload detection. When an boad error is detected, A.MUTE* is turned on, speaker relay is turned off, then "BOAD ERR" flashes on the display. � The abnormality continues for 2 seconds. � Continues. The power is shut off. � Recovery The power is shut off even if the unit recovers.
B
4. Fan stop detection operation flow in the DC abnormality detection
C
If the fan is forcibly stopped, the 'DC PROT' port becomes "L". Then an abnormality of fan is detected. When an abnormality of fan is detected, A.MUTE* is turned on, speaker relay is turned off, the "AMP_ERR" flashes on the display. � The abnormality continues for 3 seconds. � Continues. � Recovery The program restarts.
*A.MUTE : Audio mute command
D
The power is shut off. � The power key is disabled.