|
|
|
Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
The manual is well organized and is easy to read. The chapters are following normal way to proceed.
 ;
This scanned manual is well done in that most all the pages except for one is straight and clear- the way I would do them. One page was upside down but that happens. For the money that is charged on this site you get a pretty good deal. Now with complex repairs, I still prefer to us paper manuals which I have to buy at stereomanuals but the one I got here was much less than the $45 he was charging but this is a larger than normal manual for three different units. I am a picky manual user because I have used original manuals from Sony and Teac.
 ;
Very useful service manual, was exactly what i needed.Good quality,reasonable price.Thank you.
 ;
Acurate informations inside the SM and I could repair my old Sansui SC-3330 without any problems. Thanks.
 ;
I used it to repair a NAD 7030, but unfortunately, the 7045 is different !
But documentation was useful.
1
2
3
4
7.1.5 Circuit Description
A
1 Protection circuit when the edge of speaker is oveload
R325 330 R317 0.22
3 FAN detection circuit
CN305 +5.6V R405 R407 10k 1k C402 0.01
POWER Assy A
FL
FAN+ FANFAN.STOP
1 2 3
D401 R408 100k
B
R327 1.8k D301 Q305
To µ-COM FAN DCT
FRONT Assy
SP edge GND FL +5V R4243 10k To µ-COM ODCT
D410 UDZS5.1B
D303 DAP202K
When FAN is not connected between FAN+ and FAN-, or an alien substance is clogged up in the FAN at the FAN LOCK status, FAN STOP becomes the same electric potential as the FAN- (Low). � µ-COM detects it, and turn the power OFF.
B
A speaker (6�) is connected between FL and GNDFL normally. Q305 (306) (345) (346) (383) does not work because the voltage of A point is higher than B point. If a resistance value between FL and GNDFL becomes less than 1.2�, Q305 (306) (345) (346) (383) turns ON. And ODCT becomes with negative component of output level. � µ-COM detects it, and turn the power OFF.
C
2 DC detection circuit of SP terminal
R331 22k FL R332 22k FR R371 22k RL R372 22k RR DDCT R392 22k C R396 10k C391 220/10 Q384 Q385 +5V
POWER Assy
R4244 47k
D
FRONT Assy
� Q384 and Q385 are turning OFF together normally. (1) When the DC voltage of the plus (+) side was generated on the SP edge When the DC voltage of the plus (+) side was generated in L ch or R ch, Q384 turns ON and DDCT becomes Low level if VB of Q384 becomes higher than operating point. � µ-COM detects it, and turn the power OFF. (2) When the DC voltage of the minus (-) side was generated on the SP edge Q385 turns ON with + side in reverse, and DDCT works.
E
F
58
1 2
VSX-C100-S
3 4
|
|
 |
> |
|