7.1.2 Protection Circuit
DC detection
A
Detection method
XPROTECT port (A/D)R397: 56 K-ohms Less than 0.6-0.8 Vdd 2.8 sec after Mute: On Speaker Relay: Off Shifting to STBY after 3 sec "AMP ERR" flashes for 3 sec Hold the STANDBY key pressed for 10 sec. The unit will recover if the duration of detection is 3 sec or less.
Detection start time Process
Display Recovery Remarks
B
Overload detection
Detection method
XPROTECT port (A/D)R363: 27 K-ohms 0.4-0.6 Vdd 2.8 sec after Mute: On Speaker Relay: Off Shifting to STBY after 3 sec "OVERLOAD" flashes for 3 sec Press the STANDBY key.
Detection start time Process
C
Display Recovery Remarks
Fan (temperature) and short-circuit of the power supply circuit
Detection method
XPROTECT port (A/D) 0.4 Vdd or less 1.0 sec after Mute: On Speaker Relay: Off Shifting to STBY No display Hold the STANDBY key pressed for 10 sec.
Detection start time Process
D
Display Recovery Remarks
Fan stop
Detection method
E
XPROTECT port (A/D) 0.4 Vdd or less 1.0 sec after Mute: On Speaker Relay: Off Shifting to STBY No display Hold the STANDBY key pressed for 10 sec.
Detection start time Process
Display Recovery Remarks
F