Doubted for buy this manual as it is my first order here and at not have cover image, I assumed would haven't. However, within 24 hs, already possessed the link to download it. The manual are scanned correctly and have all what is needed. Includes adjustments and diagrams of all circuits. Very satisfied.
 ;
Really good quality, аll readable.! Wonderful work shop. I recommend to all!
 ;
Good quality service manual.The scheme is on A3 format and very readable.Thank you
 ;
Very good service-manual with clear electrical diagrams. Thanks you.
 ;
the manual is in quite good quality and it's in pdf. manual was send in less then 6h.
5
6
7
8
7.1.2 Protection Circuit
DC detection
Detection method
XPROTECT port (A/D)R397: 56 K-ohms Less than 0.6-0.8 Vdd 2.8 sec after Mute: On Speaker Relay: Off Shifting to STBY after 3 sec "AMP ERR" flashes for 3 sec Hold the STANDBY key pressed for 10 sec. The unit will recover if the duration of detection is 3 sec or less.
B A
Detection start time Process
Display Recovery Remarks
Overload detection
Detection method
XPROTECT port (A/D)R363: 27 K-ohms 0.4-0.6 Vdd 2.8 sec after Mute: On Speaker Relay: Off Shifting to STBY after 3 sec "OVERLOAD" flashes for 3 sec Press the STANDBY key.
C
Detection start time Process
Display Recovery Remarks
Fan (temperature) and short-circuit of the power supply circuit
Detection method
XPROTECT port (A/D) 0.4 Vdd or less 1.0 sec after Mute: On Speaker Relay: Off Shifting to STBY No display Hold the STANDBY key pressed for 10 sec.
Detection start time Process
D
Display Recovery Remarks
Fan stop
Detection method
XPROTECT port (A/D) 0.4 Vdd or less 1.0 sec after Mute: On Speaker Relay: Off Shifting to STBY No display Hold the STANDBY key pressed for 10 sec.
E
Detection start time Process
Display Recovery Remarks
F