7.3 DIAGNOSIS
POWER AMPLIFIER IC (MOTHER ASSY : IC401 and IC402) (At Bottom Side)
1
Cut six portions on the Under Base by nipper and remove a Cover. Front
3
Turn the Cover.
A
B
B
A
4 2
Diagnose the POWER AMPLIFIER IC (IC401 and IC402). Front
1
Fix the Cover with the four screws (BBZ30P080FMC). Front
IC401
22 1
IC402
22
CAUTION : After cutting it with the nipper, dispose of it not to injure by touching the cut part to an user's hand.