Probably it never existed a 1081 official service manual from Commodore, it's look more like a NAPCEC service manual & diagrams compilation of the 1084 series and his variants, like the nap6523, 8cm505, 1084S, 1084P and obviously the 1081. It's more complete than other scans and the quality of the scans also are far superior. It has two circuit diagrams variants of the 1081, mono and stereo versions. It doesn't include a diagram for the Philips CM8500 or CM8501, they look like the 1081 but they are slightly different.
 ;
Rapid, clear well done as all the scheme I downloaded from this site. Great job very functional and very useful
BACK TENSION 0.97x10 -3 - 1.71x10-3 N�m (10-17gf·cm) PLAY TORQUE 1.47x10-3 - 2.45x10-3 N·m (15-25gf·cm)
NOTE: To prevent the tape from damage, turn the guide rollers slowly. (7) By operating the tracking button (both in + and - directions) in the manual tracking mode, vary the output level of the FM waveform from maximum to minimum and vice versa to confirm that the waveform varies nearly in a flat shape. (8) When the FM waveform breaks in the level varying process, subtly adjust the height of guide rollers at every breaking point so that the waveform varies as flat as possible. Repeat the above steps 6. and 7. several times to confirm that the waveform is flat as a whole. (9) Playback the SP stairstep signal of alighment tape and adjust the tracking control to maximize the FM waveform, confirm that FM waveform variation is always flat. (10) Record the signal and play it back in both of the SP and EP modes, and confirm that the FM waveform is flat in both modes. NOTE: Among the above-mentioned adjustment steps, the items of No.9 and No.10 are needed for the EP model only.
Fig.3-3-3 3.3.3 Tape pattern Remove the exterior parts attached to the UPPER CASE ASSEMBLY so that the guide roller beside the DRUM ASSEMBLY can be rotated. � LOWER CASE ASSEMBLY � TOP OPE UNIT � CASE COVER(S),(M) ASSEMBLY � UPPER CASE (S),(M) ASSEMBLY NOTE: In performing adjustment, it is recommended that LOWER CASE ASSEMBLY and TOP OPE UNIT are attached to the main body for better operation and safety. POLE BASE (TU) (GUIDE ROLLER)
CH-2 1 field
FLATTEN WAVEFORM.
ALIGNMENT TAPE
CAUSER BY WRONG HEIGHT OF SUPPLY GUIDE ROLLER
CAUSED BY WRONG HEIGHT OF TAKE-UP GUIDE ROLLER
Fig.3-3-5
CORRECT VARIATION OF WAVEFORM
BAD VARIATION OF WAVEFORM
POLE BASE (SUP) (GUIDE ROLLER)
JIG CONNECTOR CABLE MAIN CN25 - JIG BOARD 12PIN(V_TP_FM) 13PIN(V_FF)
Fig.3-3-6 (11) Through the above steps, confirm that there occur no wrinkling and damage in the tape around the PINCH ROLLER and TU GUIDE POLE whenever the deck is in operation of Loading/Unloading, Search Rewind and at mode change from Search Rewind to play mode. If wrinkling or damage in the tape occurs around the TU GUIDE POLE, adjust the angle (slant) of the A/C HEAD to the tape. So that the tape normally runs along the lower flange of the GUIDE POLE.
(1) (2) (3) (4) (5)
(6)
Fig.3-3-4 Remove the Cover (JIG) shown on Fig.3-4-1. Connect the JIG CONNECTOR CABLE to CN25 on the MAIN BOARD ASSEMBLY as shown on Fig. 3-2-2. Observe signal at V_TP_FM with external trigger from V_FF on the JIG CONNECTOR CABLE. Playback the SP stairstep signal of the alignment tape and maximize the FM waveform by the tracking button. Set the tracking control to the center position by simultaneously pressing the tracking (-) and (+) buttons and maximize the FM waveform by the tracking button. If the observed FM waveform is not flat, adjust the height of the SUPPLY of TAKE-UP GUIDE ROLLER with the roller driver.
3-4
|
|
 |
> |
|