I work at an authorized service center and I can tell if a manual is as it should be. This one is. It may be a scan, but a very good one at that. The interesting part for me was the curcuit diagram which was scanned at high quality, making it as good as the original. I will definitely be back as a customer. I need not say this, but I will: the price was the best. Thank you owner-manuals.com .
 ;
really a very good manual even sometimes the quality is no so good as before still very readible and very very useful!
 ;
FAST very good and clear a great unexpensive job!!! very recomended for all people who are preofessional or hobbists as me!!!!!!
WCS-880
Adjustment Location:
MIC jack (J1)
RX SECTION
1. Consumption Current Check Setting:
regulated dc power supply battery terminal 3 mA Set
� TX BASE BOARD � (Component Side)
1t2t3
SW51
[RF CHANNEL]
CT2 TX OSC (12.8MHz) RV1 RV2 RV3 Adjustment TX Modulation Sensitivity Adjustment
+ �
RV51 TX Output Level Adjustment
Procedure:
battery terminal #
�VCO BOARD �
1. Connect a regulated dc power supply (1.5 V) and ampere meter. 2. Set the [RF CHANNEL] switch (SW1) to [1]. 3. Check that the value of ampere meter satisfy specified value. Specified value: 50 mA to 65 mA 2. RX Frequency Adjustment Setting:
CT1 VCO Voltage Adjustment shield case
digital voltmeter +
lead wire antenna (ANT1)
� TX BASE BOARD � (Conductor Side)
FM RF SSG
� Foot of VCO lead wire board shield antenna (ANT1) case
to TP51 RX BASE board
Q50
1/4 λ sleeve antenna
TP53 IC51
Carrier frequency: 863.4 MHz Modulation: 1 kHz, ± 20 kHz deviation Output level: � 60 dBm oscilloscope (DC range)
TP58
REC out plug (P1)
CP54
Procedure: 1. Connect the 1/4 λ sleeve antenna to a SSG, and put the antenna by the lead wire antenna (ANT2). 2.
Foot of VCO board shield case
3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14.
Connect a digital voltmeter to the TP51 on RX BASE board and the foot of FE board shield case. Connect REC out plug (P1) to an oscilloscope. Set the [RF CHANNEL] switch (SW1) to [1]. Adjust CT1 on the RX BASE board so that the value of digital voltmeter becomes 1.4 V. Confirm that the waveform of oscilloscope is sine wave. Change the carrier frequency of SSG to 864.2 MHz. Change the [RF CHANNEL] switch (SW1) to [2]. Adjust CT2 on the RX BASE board so that the value of digital voltmeter becomes 1.4 V. Confirm that the waveform of oscilloscope is sine wave. Change the carrier frequency of SSG to 864.6 MHz. Change the [RF CHANNEL] switch (SW1) to [3]. Adjust CT3 on the RX BASE board so that the value of digital voltmeter becomes 1.4 V. Confirm that the waveform of oscilloscope is sine wave.
Adjustment Location: RX BASE Board (See page 9)