Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Please tell us what you think and share your opinions with others. Be sure to focus your comments on the product. You will receive $2.00 of store credit for Your review.
 ;
Please tell us what you think and share your opinions with others. Be sure to focus your comments on the product. You will receive $2.00 of store credit for Your review.
 ;
Good copy and great customer service! There was some confusion with my order and it was resolved promptly!
 ;
Having bought a pre-owned Sony FM stereo tuner through eBay, it came without any manuals. It soon became clear that to get the best from this excellent tuner I needed a decent manual because much of the operation was not intuitive to a newboy to hi fi like me. I managed to download the official Sony multi-lingual manual from Owner-Manuals.com with no problem at all - a really quick and easy service. I'm very glad I did because I found out all the operations of the tuner and was then able to not only set it up quickly but also to get much more from it that poke-and-hope trialling would ever achieve. In my book $4.99 very well spent.
 ;
This manual is immaculate in it's accuracy. Everything is written very clearly and easy to understand. Written by a professional who wants to convey a clear and easy to understand message!!
REC ONLY: Only alarm recording will start and monitors will keep displaying the current sequence/spot images. Note: You cannot recover alarm-related operations from system controllers when REC ONLY is selected. OFF: An alarm input is not accepted via the ALARM port. The factory default setting is ON. Each alarm input's polarity is configurable in the submenu. Set ALARM PORT to ON or REC ONLY, and press the CAM (SET) button. 440 ALARM INPUT (ALARM PORT) will appear on the monitor.
440 ALARM INPUT(ALARM PORT) SWITCHER=SLAVE1(1 of 5) 1 2 3 4 5 6 7 8 NORMALLY NORMALLY NORMALLY NORMALLY NORMALLY NORMALLY NORMALLY NORMALLY OPEN CLOSE OPEN OPEN CLOSE OPEN OPEN OPEN 9 10 11 12 13 14 15 16 NORMALLY OPEN NORMALLY OPEN NORMALLY OPEN NORMALLY OPEN NORMALLY OPEN NORMALLY OPEN NORMALLY OPEN TIME ADJUST
Note: You cannot recover alarm-related operations from system controllers when REC ONLY is selected. OFF: An alarm input is not accepted via the SERIAL port. The factory default setting is ON. 460 MUX MOTION DET MUX This stands for that the unit�s motion detector is activated when a camera detects the brightness-level change and transmit an alarm signal. ON: The alarm-associated sequence/spot image is displayed on a monitor, and alarm recording will start (if a recorder is connected to the unit.) REC ONLY: Only alarm recording will start and monitors will keep displaying the current sequence/spot images. Notes: � If the Multiplexer board is not installed in the unit, you cannot enter the submenu of 460 MUX MOTION DET. � You cannot recover alarm-related operations from system controllers when REC ONLY is selected. OFF: An alarm input is not accepted by the motion detector.
Move the cursor and press the CAM (SET) button to go into the menu. SWITCHER: Select a unit (SLAVE1 to 4 and MASTER*) to configure the parameters. * In normal connection, only MASTER is displayed. After designating the unit, select the desired polarity for ALARM 1 to 16. NORMALLY OPEN: Normally Open contact is activated for the alarm input signal. NORMALLY CLOSE: Normally Close contact is activated for the alarm input signal. TIME ADJUST: This polarity enables the input of the time adjusting signal. The factory default setting is N. O.
To configure where to activate the motion detector, set MUX MOTION DET to ON or REC ONLY, and press the CAM (SET) button. The live image will be displayed. Up to 4 motion-detection areas are configured for each camera channel. Note: Black image will be displayed on the monitor if the currently selected channel has no camera connection. A �+� mark appears at the center of the monitor.
Logical camera number and sensitivity C01 LOW
+
Note: In the master-slave connection, time setting of every unit can be synchronized when the time adjusting signal is input to any unit. 450 SERIAL PORT This stands for that an alarm input is accepted via the SERIAL port. ON: The alarm-associated sequence/spot image is displayed on a monitor, and alarm recording will start (if a recorder is connected to the unit.) REC ONLY: Only alarm recording will start and monitors will keep displaying the current sequence/spot images.
Mark
The following is the setting procedure.
69
|
|
 |
> |
|