TUNER SECTION
FM SECTION
 
0 dB=1 µV
AM SECTION Setting: RADIO ON/OFF switch: ON BAND switch: AM AM Tuning Voltage Adjustment
Setting: RADIO ON/OFF switch: ON BAND switch: FM FM Tuning Voltage Adjustment
 
digital voltmeter MAIN board (VT) (GND)
+ �
digital voltmeter MAIN board (VT) (GND)

+ �
AM TUNING VOLTAGE ADJUSTMENT Adjust for a 1.0 + 0.1 Vdc reading on digital voltmeter
�0
FM TUNING VOLTAGE ADJUSTMENT Adjust for a 9.0
+0.5 �0
Vdc reading on digital voltmeter L3 108 MHz
L4 530 (531) kHz
( ): Except US model AM IF Adjustment, AM Tracking Adjustment
AM RF Signal generator Put the lead-wire antenna close to the set.
FM Tracking Adjustment
FM RF signal generator MAIN board
  
 
0.01 µF
(FM RF IN) (GND)
Modulation: 400 Hz, 30% Output level: as low possible.

Modulation: 1 kHz, 75 kHz dev. (100%) Output level: as low possible.
level meter (AC: 0.5 � 5 V range) 16 � + �
level meter (AC: 0.5 � 5 V range) 16 � set + �
set
2 jack
* Repeat the procedures in each adjustment several times, and the tracking adjustment should be finally done by the trimmer capacitors.
AM IF ADJUSTMENT Adjust for a maximum reading on level meter
2 jack
FM TRACKING ADJUSTMENT Adjust for a maximum reading on level meter L2 87.5 MHz
T1 1000 (999) kHz
( ): Except US model
AM TRACKING ADJUSTMENT Adjust for a maximum reading on level meter L1 (BAR ANTENNA) 620 (621) kHz CT1 1400 (1395) kHz
( ): Except US model
� 10 �
|
|
 |
> |
|