Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
This is a great site. I placed my order and by the next am it was available for download. Had some problems with some missing copy on some pages. Once I brought the error to the OMC's attention, the issue was resolved. I'll come back again.
 ;
Mi spiace per non poter scrivere in inglese... ma sono veramente soddisfatto del servizio offerto. Grazie..!!
 ;
The quality of this manual is good. It has all schematics and setup information for both the MDS-B3 and the MDS-B4. The scan quality is quite good, all pages are readable, This service manual also contains scans of the operating instructions from the User manual.
 ;
Quick site processing. A complete and very useful manual with all details. Thank you!
 ;
Das Service Manual war von der ersten bis zur letzten Seite sehr informativ und hilfreich. Die Darstellung aller Teile war klar und der Text gut lesbar.
Vielen Dank, das war nicht der letzte Download bei ownner-manuals.com.
SECTION 2 SERVICE NOTE
[Service Mode]
Mode which enables the mechanism to be operated with the MAIN board opened.
TP50
[MAIN Board]
AF oscillator + � 50K� TO PLUNGER FF ND701 REW TO MOTOR TP52 BATT SQUARE WAVE (SINE WAVE) 10Hz, �3.5dB BATT
1. Setting 1) Refer to �Disassembly� and remove the cabinet and open the MAIN board. 2) Connect the MAIN board to the motor and plunger using a jumper wire. Use �Extension tool (1-769-143-11) (one set 10 tools)� to make connection simple. 3) Short-circuit theTP52 and GND by soldering. 4) Turn OFF the BL SKIP switch. 5) Apply a square wave signal or a sine wave signal to TP52. (see the right figure) 6) Supply 1.3V to the battery terminals (+) and (�) using a stabilized power supply. 2. Preset State This state must be set to set the PLAY, FF, and REW modes. 1) Check that the lever (NR SW) is at the center and F/R switch (S701) is at the center. If not, set the preset state as follows. 2) Move the N/R switch (S701) according to the side faced by the lever (NR SW). 3) Turn OFF the stabilized power supply switch once and then turn it ON again so that the lever (NR SW) can be moved. Move the N/R switch (S701) according to this timing and set to the center. 3. FF REW Mode 1) Check the �2. Preset State� and press the FF switch and REW switch. 4. PLAY Mode 1) Check the �2. Preset State�. 2) Press the � switch. The lever (NR SW) will move to the F side once and then to the R side. Move the N/R switch (S701) according to this timing to set the PLAY (R side) mode. Press the � switch another time and move the N/R switch (S701) according to the movement of the lever (NR SW) to set the PLAY (N side) mode.
Note 1: If the above cannot be performed, start again from preset. Note 2: Use the remote control �, p, FF, and REW switches as much as possible. If the remote control is not available, do not touch switch with the hand and use something with a round tip to press them. Note 3: By using a headphone, the timing for moving S701 can be known by the beep.
� Side A � � Side B �
IC702 PH701 S701
N SIDE CENTER
R SIDE
[Lever (NR SW)]
Center R side Lever (NR SW) F side