Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
It was easy to order and received exactly what I needed. Only complaint would be the 24 hours you have to wait.
 ;
Manual was delivered in a timely manner and was all in English as advertised. The manuals I received when we moved into our flat were in German, Italian, and French. Having never used a steamer before, and not speaking/reading German very well, I needed an English Manual. this was a huge help.
 ;
Great Manual. This manual is available no where else. It was exactly what I was looking for. Only in German.
 ;
This GRUNDIG UV5A Owner Manual is not only an instruction manual but a total functional circuit description of the Multimeter and includes circuit diagram at the end pages. It is very helpful for repairing and calibrating the instrument. It is written in two languages English and German for international support. It was very easy to repair my unit with this document. Regards, Regis Pauly, Electrical Engineer.
 ;
The owner's manual was evetything I thought it would be. I was able to print it out using both sides of the paper in quick order, saving me a search online for a used one.
XC-E series
RESTART RESET (R.R)
The information on one screen can be extracted at any time by inputting a restart/reset signal (HD/VD) from the outside. To enter this mode, set DIP switches 6, 7, and 8 on the rear panel of a camera as shown in the table below. The setting is especially effective for the following operation.
Switch 1 2 3 4 5 6 7 8 9 0 Restart Reset (R.R) 0 0 0 0 0 1 1 1 0 0
1: ON 0: OFF
Long exposure
A high-sensitivity image is obtained by extending the exposure time of the CCD when satisfactory sensitivity cannot be obtained under other operating conditions or when observing the trail of a moving object. The exposure time is determined by the VD interval (T) period between external VD pulses as follows.
� Timing and conditions
Example 1 of Long exposure
EXT HD
Continuous signal: 15.734 kHz (XC-ES50/ES30, XC-EI50/XC-EI30)Allowable frequency value ±1%, 15.625 kHz (XC-ES50CE/ES30CE, XC-EI50CE/XC-EI30CE) Allowable frequency value ±1%
EXT VD
VD interval(T): 262.5H or more (XC-ES50/ES30, XC-EI50/XC-EI30) and less than 1 second (Recommended), 312.5H or more (XC-ES50CE/ES30CE, XC-EI50CE/XC-EI30CE) and less than 1 second (Recommended) Four or more VD pulses are required. T T T
Exposure time for Odd field Exposure time for Even field
Video output
Odd image Invalid image Even image Valid frame image
Odd and even fields are determined by the phase of the EXT HD/VD signal input from the outside.