Good site, works ok and you get what you order, no problems experienced, got my manual within a day. A++++
 ;
Original well scanned manual. Got the job done. Microwave problem found & corrected. For $5 and a new magnitron from ebay, it was a cheap and good the first shot fix. Electrical schematics allowed me to mage sure every thing else was ok before cutting and order for parts. Hard to live without.
 ;
I was very skeptical of this website, I have never downloaded manuals before. I put it on the AMEX and payed through Paypal to ensure protection. I got the manual exactly as described and now I can replace the filter capacitor for this amp. Great Price, others selling for 12.99 or more and this is the same manual. I will search out this website for other manuals. Thank you
 ;
Manual was reasonably easy to follow. I am not an engineer or know much about electronics but with the manuals help I was able to figure out the problem, identify the part required for the repair. Replacement part cost around $30. Whilst replacing the part I was telling myself, "this aint gonna work cos it seems far too easy". Took about 15 minutes to do and my plasma TV works a treat. Would never have been able to do this without the service manual.
 ;
It is OK, this manual help me to repair my dynacord
XG-NV6XE
ADJUSTING THE PC INTERFACE (CPCi-0035CE02. PC I/F Unit)
1. Setting the oscilloscope
Set the range to DC 1 V/div and 5µ/div.
2. Connecting the PC Interface
1) 2) 3) 4) 5) Fit the PC I/F in position and make sure the CON2, CON3 and CON4 connectors are all tight in place. Connect the cable between the ANALOG OUTPUT (PC computer) and the DSUB connector (INPUT1 of the proejctor). Set the projector�s input selector to the INPUT1 position. Make sure the Dsub/BNC selector is at the Dsub position. Set the PC computer in the XGA mode (1024 x 768, 60 Hz, 32-step scale). Adjust the output amplitude to 700 mVp-p (terminated with 75 ohms) for the black-to-white portions. Turn on the power.
3. Adjusting and checking the level
1) 2) 3) 4) 5) 6) Press the S5001 switch to go to the process mode. Set the SH-PHASE on the OUTPUT3 menu to 8. (Make the characters on screen clear and crisp.) Connect the oscilloscope to TP2 and adjust the M-BRIGHT data of OUPUT2 so that the signal�s black level be 1.9 V. Adjust the R-BRIGHT data of A/D so that the black level of the signal at TP1 be 1.9 V. Adjust the B-BRIGHT data of A/D so that the black level of the signal at TP2 be 1.9 V. Make sure the GAIN data on the A/D menu is 155.
4. Adjusting the DTV
1) 2) 3) 4) 5) 6) Set the switch to the BNC input terminal of INPUT1 Select the signal type of the user menu option for the component. Feed the Y signal of 480P to the G(Y) input terminal. Keep the R(Pr) and B(Pb) signals off. Connect the voltmeter to TP1, and adjust the DTV�s B-BRIGHT data to 2.65±0.02 V. Connect the voltmeter to TP3, and adjust the DTV�s R-BRIGHT data to 2.65±0.02 V. Finally press the S5001 switch again to quit the process mode.