Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Good quality service manual.It has helped me to fix my FV1800,particularly for replacing the dial cord.The scheme is on A3 format and very readable.Thank.Olivier.
 ;
This manual is complete and very readable.It was a great help for my two ICF5800L.The first one had the dial cord broken,and without the service manual it is impossible to replace it.Thank.Olivier.
 ;
This is a top quality manual. You couldn't get better if you had the original and scanned it yourself. Best price on the net as well. Diagrams are clear and complete, text is sharp and easy to read. Granted you don't get the manual the second you click pay, but the few hours you have to wait for it to be available for download isn't a problem at all. This is a very reliable company.
Very VERY pleased with the product, and will buy others. Thanks!
 ;
In a word AWESOME.
I never expected the quality and abundant content that I got with this manual. Everything you'd ever want to know from a service perspective is found in this manual, along with... as a bonus, operating instructions on how to use the unit. WOW. Very impressed with the quality of the manual. You won't be disappointed if you're looking for the EVS900 service manual.
 ;
I thank Owen-Manuals.com for the wonderful service rendered to me, and this manual which I purchased helped me a lot in servicing my Denon System, which was lying in a dead state.
Thanks Owner-Manual.com
XG-NV7XU
ADJUSTING THE PC INTERFACE (CPCi-0036CE01/03. PC I/F Unit)
1. Initializing the EEPROM
1) Press the S5001 switch to call the process mode. 2) Pick up the item S1 on the SSS menu. (The S1 is used to initialize the PC interface alone. Do not select the item S2 because otherwise the other data than the PC interface will be initialized.)
2. Adjusting the levels
1 Oscilloscope setting Set the range to DC 1 V/div. and 5 µ s/div. 2 Input signal Feed the XGA 1024x768, 60Hz gradation waveform signal and the DTV (720P for example) signal. 3 Level adjustment and checking 1) Press the S5001 switch to call the process mode. 2) Adjust R750 so that the voltage at test point TL119 be 2.6 ±0.05V. 3) Set the BRIGHT data on the A/D menu to 125. 4) Adjust the R-BRIGHT data on the A/D menu so that the voltage at TP3 be 1.7V. 5) Adjust the G-BRIGHT data on the A/D menu so that the voltage at TP2 be 1.7V. 6) Adjust the B-BRIGHT data on the A/D menu so that the voltage at TP1 be 1.7V. 7) Make sure that the GAIN data on the A/D menu is 155. 8) Connect the synchroscope to TP3. Adjust the R-D data on the A/D menu so that the signal�s white peak be 3.6V. (Be also sure that the white and black portions of the gradation are not corrupted.) 9) Connect the synchroscope to TP1. Adjust the B-D data on the A/D menu so that the signal�s white peak be 3.6V. (Be also sure that the white and black portions of the gradation are not corrupted.) 10) Connect the synchroscope to TP2. Adjust the G-D data on the A/D menu so that the signal�s white peak be 3.6V. (Be also sure that the white and black portions of the gradation are not corrupted.) 11) Feed the DTV signal instead. Enter only the Y component, not the Pb and Pr components. 12) Adjust the R-BRIGHT data on the DTV menu so that the voltage at TP3 be 2.65V. 13) Adjust the B-BRIGHT data on the DTV menu so that the voltage at TP1 be 2.65V. 14) Press the S5001 switch to exit the process mode.