I want to give you a real heads-up for your desire to enable such people as I to acquire the information I need to maintain the older types of equipment such as this Akai HXA351W. You do a swell job with all the processes you have to perform so I can have a legible, thus usable
document which does not send me crazy trying to figure out the blurry text of a bad copy.
Very well done, Thomas.
This manual is very well presented and after printing out looks about as close to an original as I think you can get. The quality is second to none.
The content of the manual is comprehensive and I think it would be well suited to an audio repair professional which I'm not but I did find it very informative and helpful.
The cost of the manual is more than covered by the money I'll save when I change the keep memory battery now I have the relavant info.
Very pleased with my purchase and can recommend it wholeheartedly as I can other manuals I've downloaded from this site.
Regards
Limey Alex
Complete MFG Service Manual at a good price FAST !
Text excerpt from page 10 (click to view)
XM-PX3BU/XM-PX3TG
Maintenance of MD pickup
1. Cleaning of pickup lens
(1) Prior to changing the pickup, clean the pickup lens. (2) For cleaning the lens, use the following cotton swab after mearsing it in alcohol. Product No. JCB-B4; Manufacturer;Nippon Cotton Swab
Procedures of changing the MD pickup
Change the MD pickup by referring to "Removing the MD pickup" in the Disassembly method.
2. Confirmation of the service life of laser diode when the service life of the laser diode has been exhausted, the following symptoms will appear.
(1) The RF output (EFM output and eye pattern amplitude) will become lower. (2) The drive current required for light emitting of laser diode will be increased.
Set the pickup to [TEST] mode according to the procedures described in the Adjustment method.
Adjust the laser power 560 W.
Power supply voltage 1.5V
20mV Adjustment
Adjust the disc. Confirm the service life according to the following flow chart: Completion of changing the MD pickup.
Can the laser power adjust under test mode?
NO
Change the pickup
YES
Is the drive current of laser diode 55mA or less?
NO
Change the pickup
Be sure to perform not only adjustment and operation of this system so carefully as not to directly look at the laser beam or touch on the body.
YES
OK.
3. Method of measuring the drive current of laser diode
When the voltage measured at the both side of carbon resistor R301 on the MD servo P.C. board (LVB20008) have become 12.1mV or over, the service life of the laser diode is judged to have been exhausted.
4. About Semi-solid state resistor of pick up
This is adjusted in the maker of pick up . Be careful please not to touch pick up .