X-NM30VCD, XR-NM3V
7 CD MECHA-2
CD Tray Open (Gear Load Aat the lower left of amechanism is turned to the left.)
Remove to the CLAMPER
A finger is put into the bottom of CHASSIS and CLAMPER is pushed from the bottom. The end of CLAMPER is united with the cut in right and left of CHASSIS, and the upper surface of CLAMPER is raised by hand and turned counterclockwise.
7 DIAGNOSIS OF CD MECHA ASSY
When diagnosing the CD MECHA Assy, use the following Flexible Cable and Connector Assys for service. Motor Assy - VCD PWB Assy ( 6 pin Flexible Cable) : No. GGD1275
When removing a tray, a stopper is raised upwards and a tray is pulled.
1
2
Control Assy - VCD PWB ASSY 27P Flexible Cable : No. GGD1237 A tray is attached, and a tray is put in at the time, making it move to the right for a while so that a cam slider may be gone into the slot on the tray.
62
|