Superb rendition. Drawings (schematics) complete and unabridged. I do a great deal of vintage audio restoration. Documentation is essential for successful repairs. I have found sources over the years that offer good documentation, but rarely all that is necessary. Owner's Manuals has filled that void with complete and legible documentation. They have narrowed my "favorites" to a more manageable collection. This Denon manual in particular contained the latest revisions level, and offered alterations favorable to updating the item. The Illustrated Parts Breakdown (IPB) was well enough detailed to simplify part symbols and physical locations. You will not be disappointed!
 ;
Clear and concise. Saved me a lot of time and money.
 ;
Superb manual. Exactly what I ordered and made available in a very timely manner.
 ;
very fast detailed and accurate hope to do business again
 ;
This was precisely what I was looking for. Complete and good quality!
XP-EV600/EV600B/EV600D SECTION 4 ELECTRICAL CHECKING
The CD section adjustments are done automatically in this set. In case of operation check, confirm that RF level. Precautions for Check 1. Perform check in the order given. 2. Use YEDS-18 disc (Part No.: 3-702-101-01) unless otherwise indicated. 3. Power supply voltage requirement : DC4.5 V in DC IN jack. (J201) VOLUME button : Minimum HOLD switch : OFF RF Level Check Condition: � Hold the set in horizontal state. Connection:
oscilloscope (AC range) MAIN board TJ401 (RF) TJ403 (RF GND)
+ �
Checking Location: � MAIN board (SIDE B) �
Procedure: 1. Connect the oscilloscope to the test points TJ401 (RF) and TJ403 (RF GND) on the MAIN board. 2. Set a disc. (YEDS-18) 3. Press the u button. 4. Check the oscilloscope waveform is as shown below. A good eye pattern means that the diamond shape (�) in the center of the waveform can be clearly distinguished.
RF Signal reference Waveform (Eye Pattern)
VOLT/DIV : 100 mV (With the 10:1 probe in use) TIME/DIV : 500 ns
TJ403 (RF GND) TJ401 (RF)
RF level 0.45 to 0.70 Vp-p
IC404 IC402
To watch the eye pattern, set the oscilloscope to AC range and increase the vertical sensitivity of the oscilloscope for easy watching.
5.
Stop revolving of the disc motor by pressing the x button.
11
|
|
 |
> |
|