Probably it never existed a 1081 official service manual from Commodore, it's look more like a NAPCEC service manual & diagrams compilation of the 1084 series and his variants, like the nap6523, 8cm505, 1084S, 1084P and obviously the 1081. It's more complete than other scans and the quality of the scans also are far superior. It has two circuit diagrams variants of the 1081, mono and stereo versions. It doesn't include a diagram for the Philips CM8500 or CM8501, they look like the 1081 but they are slightly different.
 ;
Rapid, clear well done as all the scheme I downloaded from this site. Great job very functional and very useful
XP-EV600/EV600B/EV600D SECTION 4 ELECTRICAL CHECKING
The CD section adjustments are done automatically in this set. In case of operation check, confirm that RF level. Precautions for Check 1. Perform check in the order given. 2. Use YEDS-18 disc (Part No.: 3-702-101-01) unless otherwise indicated. 3. Power supply voltage requirement : DC4.5 V in DC IN jack. (J201) VOLUME button : Minimum HOLD switch : OFF RF Level Check Condition: � Hold the set in horizontal state. Connection:
oscilloscope (AC range) MAIN board TJ401 (RF) TJ403 (RF GND)
+ �
Checking Location: � MAIN board (SIDE B) �
Procedure: 1. Connect the oscilloscope to the test points TJ401 (RF) and TJ403 (RF GND) on the MAIN board. 2. Set a disc. (YEDS-18) 3. Press the u button. 4. Check the oscilloscope waveform is as shown below. A good eye pattern means that the diamond shape (�) in the center of the waveform can be clearly distinguished.
RF Signal reference Waveform (Eye Pattern)
VOLT/DIV : 100 mV (With the 10:1 probe in use) TIME/DIV : 500 ns
TJ403 (RF GND) TJ401 (RF)
RF level 0.45 to 0.70 Vp-p
IC404 IC402
To watch the eye pattern, set the oscilloscope to AC range and increase the vertical sensitivity of the oscilloscope for easy watching.
5.
Stop revolving of the disc motor by pressing the x button.
11
|
|
 |
> |
|