Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
|
There are currently no product reviews.
 ;
Hard to find manual was ready the next day. Scans were very legible (including schematics). All the essential parts of the service manual were present (adjustment procedure, schematics, and parts list). It would have been nice if the rest of the manual was included (disassembly procedure, theory of operation, etc.).
 ;
The Service Manual for the Kenwood KR-V55R provided by owner-manuals.com was as described/advertised. The contents provided the necessary information to effect a diagnosis of the unit. The schematics above all else was instrumental in tracing the the signal flow from component to component.
 ;
This manual was the factory original. Excellent value and contained all the details I needed. Easy dowwnload provided the information when I needed it.
 ;
Impeccable, document très complet. Perfect, i get all i need. All schematic are correct. Thanks
 ;
The manual is of better quality compared to other. I found it less expensive and therefore it it is the best buy cost vs quality.
SECTION 3 MECHANICAL ADJUSTMENTS
1. Clean the following parts with a denatured-alcohol-moistened swab: playback head pinch roller rubber belt capstan idler 2. Demagnetize the playback head with a head demagnetizer. 3. Do not use a magnetized screwdriver for the adjustments. 4. The adjustments should be performed with the power supply voltage (14.4 V) unless otherwise noted. � Torque Measurement
Mode Forward Forward Back Tension Reverse Reverse Back Tension FF, REW CQ-102RC Torque Meter CQ-102C Meter Reading 2.46 � 5.39 mN�m (25 � 55 g�cm) (0.35 � 0.76 oz�inch) 0.15 � 0.39 mN�m (1.5 � 4 g�cm) (0.02 � 0.06 oz�inch) 2.46 � 5.39 mN�m (25 � 55 g�cm) (0.35 � 0.76 oz�inch) 0.15� 0.39 mN�m (1.5 � 4 g�cm) (0.02 � 0.06 oz�inch) 4.91 � 14.70 mN�m (50 � 150 g�cm) (0.69 � 2.08 oz�inch)
SECTION 4 ELECTRICAL ADJUSTMENTS
TEST MODE This set have the test mode function. In the test mode, FM Auto Seek/Stop Level, FM RDS S-Meter adjustments and MW Auto Seek/Stop Level check can be performed easier than it in ordinary procedure. <Set the Test Mode> 1. Turn ON the regulated power supply. (All LEDs on the set lights up, and the clock is displayed.) Note: Press the [OFF] button, if the clock is not displayed. 2. Push the preset [4] button. 3. Push the preset [5] button. 4. Press the preset [1] button for more than two seconds. 5. Then the display indicates all lights, the test mode is set. <Release the Test mode> 1. Push the [OFF] button.
CQ-102C
CQ-102RC
CQ-201B
� Tape Tension Measurement
Mode Forward Reverse Tension Meter CQ-403A CQ-403R Meter Reading more than 5.89 mN�m (more than 60 g) (more than 2.12 oz)