Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
- GENERAL
- Location of Controls
- Installation
- Connections
- DISASSEMBLY
- ASSEMBLY OF MECHANISM DECK
- MECHANICAL ADJUSTMENTS
- ELECTRICAL ADJUSTMENTS
- Test Mode
- Tape Deck Section
- Tuner Section
- DIAGRAMS
- IC Pin Function Description
- Printed Wiring Boards - MAIN Section
- Schematic Diagram - MAIN Section
- Printed Wiring Board - CONTROL Section
- Schematic Diagram - CONTROL Section
- EXPLODED VIEWS
- ELECTRICAL PARTS LIST
There are currently no product reviews.
 ;
muy buen manual por lo completo de este algunos esquemas estan muy divididos lo que hace algo dificil el seguimiento.
 ;
very good manual, with detail and clarity in esquematic diagrams and waveforms .
 ;
Very quality copy of original service manual, which contains the circuit diagrams, PCB and lists of components, well as recommendation for calibration procedures of device, also everything else, that need for repair, tuning and use this oscilloscope.
All presented copies have high-resolution, so you can view all in detail.
This manual will very useful for simple owners and for repairers.
I recommend these manual, because myself is owner of Philips PM3216 and I need sometimes servicing these oscilloscope (principally calibrating).
Also, these document is an example of excellent design of technical documentation.
 ;
Excellent printing quality.
A complete and very usefull service manual with all details.
GREAT SERVICE AT VERY LOW PRICE!
A+++++++++++++++++++++++++
 ;
manual excelente completo , diagramas y esquemas bien presentados y buena calidad de imagen.
SECTION 4 MECHANICAL ADJUSTMENTS
1. Clean the following parts with a denatured-alcohol-moistened swab: playback head pinch roller rubber belt capstan idler 2. Demagnetize the playback head with a head demagnetizer. 3. Do not use a magnetized screwdriver for the adjustments. 4. The adjustments should be performed with the power supply voltage (14.4 V) unless otherwise noted. � Torque Measurement Mode Forward Forward Back Tension Reverse Reverse Back Tension FF, REW Torqu Meter CQ-102C CQ-102C CQ-102RC CQ-102RC CQ-201B Meter Reading 35�65 g�cm (0.49�0.90 oz�inch) 0.5�5.0 g�cm (0.01�0.07 oz�inch) 35�65 g�cm (0.49�0.90 oz�inch) 0.5�5.0 g�cm (0.01�0.07 oz�inch) 60�200 g�cm (0.83�2.78 oz�inch)
SECTION 5 ELECTRICAL ADJUSTMENTS
TEST MODE This set have the test mode function. In the test mode, FM Auto Scan/Stop Level and MW Auto Scan/Stop Level adjustments can be performed easier than it in ordinary procedure. <Set the Test Mode> 1. Set the �OFF� mode. 2. Push the preset 4 button. 3. Push the preset 5 button. 4. Press the preset 1 button for more than two seconds. 5. Then the display indicates all lights, the test mode is set. <Release the Test mode> 1. Push the �OFF� button.
� Tape Tension Measurement Mode Forward Reverse Torqu Meter CQ-403A CQ-403R Meter Reading more than 60 g (more than 2.12 oz)
� 17 �
|
|
 |
> |
|