Categories
|
|
Information
|
|
Featured Product
|
|
|
 |
|
- GENERAL
- Location of Controls
- Installation
- Connections
- DISASSEMBLY
- ASSEMBLY OF MECHANISM DECK
- MECHANICAL ADJUSTMENTS
- ELECTRICAL ADJUSTMENTS
- Test Mode
- Tape Deck Section
- Tuner Section
- DIAGRAMS
- IC Pin Function Description
- Printed Wiring Boards - MAIN Section
- Schematic Diagram - MAIN Section
- Printed Wiring Board - CONTROL Section
- Schematic Diagram - CONTROL Section
- EXPLODED VIEWS
- ELECTRICAL PARTS LIST
There are currently no product reviews.
 ;
This manual is very good. 303 pages scanned in a very high resolution. My camera has bad, leaking capacitors which all of the V5000 models are suffering from these days.
There is a huge part list with all capacitors, transistors etc. in this manual which helped me a lot. Otherwise I would not have been able to buy replacement parts.
The dissassembly guide is very enormous and detailed. Unlike on the Panasonic MS1 manual I downloaded here it actually looks like the real parts look. And the screws are labeled correctly, so you shouldn't have any left after the repair. ;)
 ;
has all the schematics you could need,and very well laid out format also has all part numbers along with an exploded view which is helpful
 ;
Very nice to have! Now it is no problem to understand how it is put together.
Helps me a lot.
 ;
good scans, all is clear. all pages in order. recommended
 ;
Très-très bon site, facile, très bon prix.
Au futur besoin, je n’hésiterais à faire appel à vous.
Merci
SECTION 4 MECHANICAL ADJUSTMENTS
1. Clean the following parts with a denatured-alcohol-moistened swab: playback head pinch roller rubber belt capstan idler 2. Demagnetize the playback head with a head demagnetizer. 3. Do not use a magnetized screwdriver for the adjustments. 4. The adjustments should be performed with the power supply voltage (14.4 V) unless otherwise noted. � Torque Measurement Mode Forward Forward Back Tension Reverse Reverse Back Tension FF, REW Torqu Meter CQ-102C CQ-102C CQ-102RC CQ-102RC CQ-201B Meter Reading 35�65 g�cm (0.49�0.90 oz�inch) 0.5�5.0 g�cm (0.01�0.07 oz�inch) 35�65 g�cm (0.49�0.90 oz�inch) 0.5�5.0 g�cm (0.01�0.07 oz�inch) 60�200 g�cm (0.83�2.78 oz�inch)
SECTION 5 ELECTRICAL ADJUSTMENTS
TEST MODE This set have the test mode function. In the test mode, FM Auto Scan/Stop Level and MW Auto Scan/Stop Level adjustments can be performed easier than it in ordinary procedure. <Set the Test Mode> 1. Set the �OFF� mode. 2. Push the preset 4 button. 3. Push the preset 5 button. 4. Press the preset 1 button for more than two seconds. 5. Then the display indicates all lights, the test mode is set. <Release the Test mode> 1. Push the �OFF� button.
� Tape Tension Measurement Mode Forward Reverse Torqu Meter CQ-403A CQ-403R Meter Reading more than 60 g (more than 2.12 oz)
� 17 �
|
|
 |
> |
|